期刊文献+

地源热泵地埋管换热器传热研究(3):变热流边界条件下单U形地埋管换热器的非稳态传热特性 被引量:10

Heat transfer of ground heat exchanger for GSHP(3):transient heat transfer characteristic of U-type ground heat exchanger with variable heat flow boundary
在线阅读 下载PDF
导出
摘要 采取数值计算与解析计算相结合的方法,研究变热流边界条件下单U形地埋管换热器的非稳态传热特性。以钻孔壁为边界,将计算区域分为两个部分,钻孔内区域采用稳态解析计算模型,钻孔外土壤区域采用有限容积法。研究了埋管出口流体温度、钻孔瞬时平均壁温、单位长度吸热量以及距钻孔一定距离处土壤温度分布随运行时间的变化规律。计算结果为地源热泵系统的动态模拟、优化设计及改进提供了参考。 Studies the transient heat transfer characteristic with numerical calculation method and analytic solution. Divides the calculation area into two parts based on the boundary of borehole wall, the calculation method is steady analytic solution for the area in the borehole, and the finite volume method for the soil area. Obtains the variety patterns of outlet water temperature, transient borehole wall temperature, heat exchange capacity per length and temperature distribution in certain distances from the pipe. The result can be used as a reference for the dynamic simulation, optimum design and improvement of GSHP.
机构地区 西南交通大学
出处 《暖通空调》 北大核心 2009年第12期10-15,共6页 Heating Ventilating & Air Conditioning
基金 中国博士后面上资助项目(编号:20080431241) 四川省青年科技基金项目(编号:09ZQ026-076) 北京市重点实验室开放课题(编号:2008K09) 西南交通大学科学研究基金项目(编号:2008B17)
关键词 地源热泵 U形埋管 变热流边界 非稳态传热 解析计算 数值计算 ground-source heat pump, U-type transfer, analytic solution, numerical calculation buried pipe, variable heat flow boundary, transient heat
作者简介 袁艳平,男,1973年6月生,博士后,副教授 610031 四川省成都市西南交通大学机械工程学院 (0)13880871068 E-mail:ypyuan@home.switu.edu.cn
  • 相关文献

参考文献14

  • 1Deerman J D, Kavanaugh S R. Simulation of vertical U-tube groun&coupled heat pump systems using the cylindrical heat source solution [G]//ASHRAE Trans, 1991,97 (1) : 287- 294.
  • 2Yavuzturk C, Spitler J D, Ree S J. A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers[ G]// ASHRAE Trans, 1999,105(2) :465- 474.
  • 3Bi Yuehong, Chen Lingen, Wu Chih. Ground heat exchanger temperature distribution analysis and experimental verification [J]. Applied Thermal Engineering, 2002,22(2) : 183-189.
  • 4Katsunori Nagano, Takao Katsura, Sayaka Takeda. Development of a design and performance prediction tool for the ground source heat pump system[J]. Applied Thermal Engineering, 2006, 26 ( 14/15):1578-1592.
  • 5Lei T K. Development of a computational model for a ground-coupled heat exchanger [ G ]//ASHRAE Trans, 1993,99(1) : 149-159.
  • 6Rottmayer S P, Beckman W A, Mitchell J W. Simulation of a single vertical U-tube ground heat exchanger in an infinite medium [G]//ASHRAE Trans, 1997,103(2) : 651- 659.
  • 7Lee C K, Lam H N. Computer simulation of borehole ground heat exchangers for geothermal heat pump systems[J].Renewable Energy, 2008,33(6): 1286-1296.
  • 8Gopal Bandyopadhyay, William Gosnold, Michael Mann. Analytical and semi-analytical solutions for short-time transient response of ground heat exchangers [J].Energy and Buildings, 2008, 40 (10): 1816-1824.
  • 9Zeng Heyi, Diao Nairen, Fang Zhaohong. Heat transfer analysis of boreholes in vertical ground heat exchangers[J].International Journal of Heat and Mass Transfer, 2003,46(23):4467-4481.
  • 10杨卫波,施明恒.地源热泵中U型埋管传热过程的数值模拟[J].东南大学学报(自然科学版),2007,37(1):78-83. 被引量:27