摘要
分析雷电的产生机理和破坏途径,总结FPSO直击雷防护的重点,以长青号浮式生产储油船为例,提出对FPSO系统中孤立金属塔类等危险装置的直击雷防护措施。
Through analyzing the mechanism of lightning and the way of destroy, the focus of the lightning protection for FPSO was summarized. The Bohai Changqing FPSO was taken as an example to bring up the direct lighting flash protective measures for the metal tower and other dangerous types of devices, which provide a theoretical and practical protection for the FPSO system about security operations at sea.
出处
《船海工程》
2009年第6期99-101,123,共4页
Ship & Ocean Engineering
关键词
FPSO系统
直击雷
保护角法
防护措施
FPSO system
direct lighting flash
protection of the law angle
protective measures
作者简介
罗佳俊(1984-),男,大学.技术员。研究方向:雷电防护,防雷工程设计施工。E-mail:tjfanglei@yahoo.com