提出了用银基汞膜电极阳极溶出伏安法测定地面水中铊的方法。对方法的精密度、回收率及干扰离子的消除进行了试验。在0016mol/LHAc-002mol/LNaAc缓冲溶液(pH=48)和0006mol/LEDTA为底液的溶液中,银基汞膜电极在外加电压-100V下电解富集2min~10min,再在-100V至000V间进行阳极溶出,成功地测定了地面水中铊的含量。铊浓度在04μg/L~18μg/L之间线性关系良好,γ=09999,检测限为03μg/L。
The paper detailed the method of determining Thallium in surface water by anode-deposition current-voltage method with silver-mercury film electrode. The precision,recovery and interference were tested. In HAc(0 016 mol/L)-NaAc(0 02 mol/L) buffer solution (pH4 8) and EDTA 0 006 mol/L solution,silver-mercury electrode was voltaged -1 00V for 2 min~10 min, then voltaged between -1 00V and 0 00 V with anode deposition to determine Thallium. With Thallium concentration between 0 4 μg/L~1 8 μg/L,the method has good lineage and γ=0 9999.The detecting limit is 0 3 μg/L.