期刊文献+

新型巯基化合物自组装膜修饰电极对铜离子的检测 被引量:4

Detection of Copper Ion on a New Sulfur Compound Self-assembly Membrane-modified Electrode
在线阅读 下载PDF
导出
摘要 合成了一种新型的巯基化合物,在金电极上形成自组装膜,以循环伏安法和电化学阻抗法(EIS)对自组装膜进行表征,基于其末端的氨基对铜离子的配位效应,实现了对铜离子的快速检测,并优化了沉积时间、pH、静止时间、沉积电压等检测条件。同时研究了铜离子与人血清白蛋白的相互作用。结果表明,该组装膜在2×10-7~2.5×10-3mol/L范围内对铜离子有线性响应,检出限为0.05μmol.L-1,其与蛋白的结合常数为2.20×103L/mol。银离子、锌离子等对铜离子的测定几乎没有干扰。 A new sulfur-compound was synthesized, and a self-assembly membrane was formed on a gold electrode. The electrochemical characteristics of this film were studied by cyclic voltammetry and AC impedance technique. Copper ion could be detected due to its coordination with amino groups of the film. The detection conditions, such as deposition time, pH of solution, station time and depo- sition potential, were discussed in detail. The interaction of copper ion with human serum albumin (HSA) was also investigated. The results showed that there was a linear relationship between log- arithm of the current and logarithm of the copper concentration in the range of 2×10^-7~2.5×10^-3mol/L, and the detection limit was 0.05 μmol·L-1. The binding constant between HSA and cop- per ions was 2. 20 ×10^3 L/tool. The interferences of other metal ions, such as Ag+ and Zn2+ , were investigated, and results showed that these metal ions don't interfered with the determination of copper ions.
出处 《分析测试学报》 CAS CSCD 北大核心 2009年第9期1031-1034,1039,共5页 Journal of Instrumental Analysis
基金 化学生物传感与化学计量学国家重点实验室开放基金资助项目(2007011) 广东省高校优秀青年创新人才培育项目
关键词 自组装 人血清白蛋白 膜修饰电极 巯基化合物 self-assembly copper human serum albumin membrane modified electrode sulfur-compound
作者简介 第一作者:钟燕(1985-),女,广东河源人,硕士研究生 通讯作者:刘英菊,Tel:020-85280325,E-mail:yingjuliu@scau.edu.cn
  • 相关文献

参考文献13

二级参考文献69

共引文献41

同被引文献43

  • 1Lin M, Cho M S, Choe W Set al. Electrochemical Detection of Copper Ion using a Modified Copolythiophene Electrode[J]. Electrochimica Acta,2009,55(23) :7012-7017.
  • 2Yan B L,Worsfold P J. Determination of Cobalt(Ⅰ).Copper( Ⅰ ) and Iron( Ⅰ) by Ion Chromatography with Chemiluminescence Detection[-J]. Analytica Chimica Acta, 1990,236(2) : 287-292.
  • 3Lara F J,Garcia-Campa? a A M, Aaron J J. Analytical Applications of Photoinduced Chemiluminescence in Flow Systems-A Review [J]. Anal ytica Chimica Acta , 2010, 679 (1) :17-30.
  • 4Gamiz-Gracia L,Garcia-Campana A M,Huertas-Perez J F. Chemiluminescence Detection in Liquid Chromatography:Applications tc Clinical, Pharmaceutical, Environmental and Food Analysis-A Review[J]. Analytica Chimica Acta, 2009,640 (1) : 7- 28.
  • 5Rao T. P, Daniel R,Kala, S. Metal Ion-imprinted Polymers-Novel Materials For Selective Recognition of Inorganics[-J]. Analytica Chbnica Acta,2006,578(2) : 105-116.
  • 6Li Y. M. , Zhang X. L. , Zhu B. C. , Xue J. , Zhu Z. , Tan W. H. , Analyst, 2011, 136, 1124-1128.
  • 7Fan C. L. , Dai X. , Yang W. M. , Wang X. F. , Yang Y. X. , Chem. Res. Chinese Universities, 2009, 25 (5) , 620--623.
  • 8Ma X. , Liu J. , Du Y. G. , Wei G. H. , Wei D. B. , Sci. China Chem. , 2012, 55(4) , 626--631.
  • 9Goswami S. , Sen D. , Das N. K. , Org. Left. , 2010, 12(4) , 856-859.
  • 10Zhou Y. , Wang S. X. , Zhang K. , Jiang X. Y. , Angew. Chem. Int. Ed. , 2008, 120, 7564-7566.

引证文献4