摘要 文章提出了数控加工中心是一种高效率的机床,阐述了刀具监控对加工质量的重要影响。作者认为相对于渗透检测、射线检测、超声波检测、红外线成像技术、涡流检测等无损检测技术,涡流检测属于非接触性测量,检测速度快,容易实现与加工中心的连接。文章将涡流技术中的脉冲涡流检测技术认定为刀具裂纹的测量技术。另外还对测量装置在机床上的安装位置进行探讨。提出利用加工中心中CNC装置的计算机功能加入检测模块以完成检测。 This paper mentions that the CNC machining center is a high productive machine tool, and the inspection of cutting tools has important affection to the machining quality.The writer thinks that relative to penetrating testing, ray testing, supersonic testing, infrared vision technique, etc nondestructive testings, the eddy current testing is a noncontactive testing, its testing speed is quick and is easy to realize its connectionwith the machining center.Within the eddy current techniques this paper decides that the pulsed eddy current testing[ PET ] is used to inspect whether any crack happens in such cutting tools.Besides, how to set up such a PET system on the working table of a machining center is discussed.Increasing a testing module to the CNC function of the machining center to implement such a testing system is studied.
出处 《组合机床与自动化加工技术》 北大核心 2009年第6期51-53,共3页 Modular Machine Tool & Automatic Manufacturing Technique
关键词 刀具裂纹 无损检测 脉冲涡流检测 tool crack nondestructive testing pulse eddy current testing
作者简介 董友耕(1963-),男。西安工程大学机电学院机制教研室讲师,主要研究领域是数控机床和数控在线检测,(E—mail)dongyougeng@163.com。
  • 相关文献

参考文献6

二级参考文献20

  • 1张玉华,罗飞路,白奉天,曹雄恒.涡流检测缺陷定量评估的研究[J].无损检测,2004,26(11):575-579. 被引量:7
  • 2缪鹏程,米小兵,张淑仪,张仲宁,洪毅.超声红外热像检测中缺陷发热的瞬态温度场的有限元分析[J].南京大学学报(自然科学版),2005,41(1):98-104. 被引量:20
  • 3[1]SMITH R A,HUGO G R.Transient eddy current NDE for aging aircraft-capabilities and limitations.Insight,2001,43(1):14-25.
  • 4[2]BRUNO L,YVES J,BABOUX J C.Pulsed eddy current signal analysis:application to the experimental detection and characteriazation of deep flaws in highly conductive materials.NDT & Einternational,1997,30(3):163-170.
  • 5[3]VALLESE L M.Diffusion of pulsed currents in conductors.Journal of Applied Physics,1954,25(2):225-228.
  • 6Moulder J C, Bieber J A, Ward W W, et al. Scanned pulsed-eddy-current instrument for non-destructive inspection of aging aircraft[J]. SPIE, 1996, 2945: 2-13.
  • 7Smith R A,Hugo G R. Transient eddy current NDE for ageing aircraft-capabilities and limitations[J]. Insight,2001,43(1): 14-25.
  • 8Clauzon T, Thollon F, Nicolas A. Flaws Characterization with Pulsed Eddy Currents N. D. T[J]. IEEE Transactions on Magnetics, 1999, 35(3): 1873-1876.
  • 9Dai X W, Ludwig R, Palanisamy R. Numerical Simulation of pulsed Eddy-Current Nondestructive Testing Phenomena[J]. IEEE Transactions on Magnetics, 1990, 26(6): 3089-3096.
  • 10Sophin A, Tian G Y, Taylor D, et al. A feature extraction technique based on principal component analysis for pulsed eddy current NDT[J]. NDT & E International, 2003, 36: 37-41.