摘要
                
                    利用温度、热流巡检仪以及便携式热舒适仪等装置对太阳能新风房间与普通房间的温度、热流等参数变化进行了对比实验。分析冬季工况下太阳能新风房间热特性情况,同时利用CFD技术对太阳能新风房间及普通房间的各项热物理参数进行模拟,并与实验结果进行对比分析。研究表明,在相同的室外环境下,太阳能新风房间使得室内温度比普通房间高出1~2℃,且波动幅度小于普通墙房间。
                
                With the help of a patrolling instrument, an electron micro demeanor and a portable heat comfort test instrument, contrast experiments about the Solar Wall (SW) room and the ordinary room were carried. Based on the CFD simulation, the thermal characteristic of SW room in winter and the building energy saving of SW technology were discussed. It shows that under the same outdoor environment, the temperature of the SW room is higher than ordinary room about 1-2 ℃, and the temperature fluctuation of SW room is lower.
    
    
    
    
                出处
                
                    《建筑热能通风空调》
                        
                        
                    
                        2009年第3期68-71,19,共5页
                    
                
                    Building Energy & Environment
     
            
                基金
                    国家外国专家局重点项目(DZ20062100070)
                    建设部科技攻关项目(05-k3-26)
                    辽宁省教育厅科技攻关项目(2004D253)
            
    
                关键词
                    太阳能新风
                    热环境
                    CFD
                    模拟
                
                        Solar Wall (SW), thermal environment, CFD, simulation
                
     
    
    
                作者简介
作者简介:宁经洧(1980-),男,硕士研究生;辽宁省沈阳市沈阳建筑大学市政与环境工程学院(110168);E-mail:ningjingwei@gmail.com