水样中54Mn的浓度在0.177—51.2Bq·L-1范围内,用4种不同放射性活度水平的54Mn试样进行比对实验,以确定《水中锰-54的分析方法》的精密度。测得该法的重复性r和再现性R值。
he purpose of this work is to determine the precision of analytical method for 54Mn in water. A series of intercomparison tests are carried out for water samples with four different radioactive levels of 54Mn when the concentration of 54Mn in water is in the range of 0.177—51.2 Bq·L -1. Corresponding to various radioactive levels, the values of repeatability r and reproducibility R are determined for this method.