摘要
以天津市潘楼垃圾中转站为例,分析了我国已建垃圾压缩车间二层防火疏散设计存在的问题,提出既可满足GB50016—2006建筑设计防火规范的相关要求又可降低工程造价的设计方案。
Taking Panlou Waste Transfer Station in Tianjin as an example, the existing problems in fire prevention and evacuation design for waste compaction workshop on the second floor in China were analyzed, and a design plan that did not only meet the requirement of GB 50016-2006 Code of Design on Building Fire Protection and Prevention, but also reduce engineering cost, was put forward.
出处
《环境卫生工程》
2008年第6期24-25,共2页
Environmental Sanitation Engineering
关键词
垃圾中转站
压缩车间
二层防火疏散
设计方案
waste transfer station
compaction workshop
fire prevention and evacuation on the second floor
design plan
作者简介
乔毅(1974-),建筑师,注册造价工程师,在读工程硕士主要从事总图、建筑设计及工程造价编制。