期刊文献+

水轮机调速器参数对调压室稳定断面积的影响研究 被引量:1

Study on the influence of the parameter of turbine governor to stable sectional area of surge tank
在线阅读 下载PDF
导出
摘要 水电站调压室的稳定断面积一般是按照著名的托马准则来确定的。托马稳定断面积计算公式是在多种假定条件下简化得到的,对于中低水头电站的调压室来说,托马稳定断面积往往较大。通过工程实例采用非线性数学模型研究了水轮机调速器参数对调压室水位波动稳定性的影响,提出了调压室水位波动稳定性的品质指标,论证了调压室可以采用小于托马公式计算的断面积。 The stable sectional area of surge tank is usually designed according to the famous Thoma criterion. Its formula is educed under many hypotheses. However, for the hydropower stations of low delivery head, the cross--sectional area of chamber tends to be lager than that of other types. Joining an engineering example, the effect of the parameter of governor on stable sectional area of surge tank has been analyzed by using the nonlinear mathematical model, a quality index of the water level fluctuation in surge tank is put forward, and a smaller sectional area can be used to surge tank is proved.
出处 《吉林水利》 2008年第11期16-18,共3页 Jilin Water Resources
关键词 调速器参数 调压室 稳定断面积 the parameter of governor surge tank stable sectional area
作者简介 高晓光(1981-),男,黑龙江省齐齐哈尔市龙江县人,四川大学研究生,主要从事水力过渡过程研究。
  • 相关文献

参考文献3

二级参考文献1

  • 1姚慰城,常兆堂,寿梅华,董兴林.水电站调压井稳定断面问题的研究[J].水利学报,1981,(6):86-91.

共引文献9

同被引文献3

  • 1马善定,汪如泽.水电站建筑物(第2版)[M].北京:中国水力水电出版社,1995,101-159.
  • 2DL/T563-2004,水轮机电液调节系统装置技术规程[s].
  • 3DL/T5058-1996.水电站调压室设计规范[S].[S].,..

引证文献1

二级引证文献1