期刊文献+

装配整体式钢筋混凝土框架柱榫式接头的试验研究 被引量:27

EXPERIMENTAL STUDY OF TENON CONNECTION FOR PRECAST MONOLITHIC R.C.FRAME COLUMN
在线阅读 下载PDF
导出
摘要 对以往的装配整体式钢筋混凝土框架柱的榫式接头进行了改进,即把钢筋混凝土榫头改用钢管混凝土榫头,柱纵筋的焊接或冷挤压套筒连接改用滚轧直螺纹套筒连接。低周反复水平荷载作用下的6根框架柱的试验结果以及施工工艺的试验表明,这种榫式柱的受力是可靠的,施工是方便的,可以用于实际工程。最后提出了一些设计和施工建议。 The traditional tenon connection of precast monolithic R.C. frame columns is improved. In which the concretefilled steel tubular tenon instead of the R.C. tenon and the longitudinal steel bars connected by wiled parallel thread sleeve instead of welding or sleeve-cold-extruding connection technologies. The test results of 6 frame column specimens subjected to low-cycle reversed horizontal load and the test results of construction technologies show that the suggested tenon connection of frame columns is reliable and convenient, and it can be used in the practical engineering. Some suggestions on design and construction are also proposed.
出处 《工业建筑》 CSCD 北大核心 2008年第10期48-52,47,共6页 Industrial Construction
关键词 装配整体式 框架柱 钢管混凝土榫头 滚轧直螺纹钢筋连接 precast monolithic frame column concrete-filled steel tubular rabbet rolled parallel thread splicing of rebar
作者简介 罗青儿 男 1976年9月出生 博士研究生 E—mail:luoqinger@163.com
  • 相关文献

参考文献4

  • 1CECS43:92钢筋混凝土装配整体式框架节点与连接设计规程
  • 2程文,李爱群,张晓峰,吴亦君.钢筋砼柱的轴压比限值[J].建筑结构学报,1994,15(6):25-30. 被引量:56
  • 3CECS28:90.钢管混凝土结构设计与施工规程.[S].,..
  • 4JGJ 101-96 建筑抗震试验方法规程.

二级参考文献4

  • 1林大炎,1981年
  • 2程文--,工程抗震,1992年,3期
  • 3王传志,钢筋混凝土结构理论,1985年
  • 4过镇海,建筑结构学报,1982年,12期