摘要 对脉冲γ射线束测量中常用的一种由塑料闪烁体ST401组成的电流型闪烁探测器的γ能量响应进行了实验研究。利用反应堆、加速器等多种手段产生一系列准单能的γ射线,实验标定了包括137Cs、60Co在内的13个能量点,得到了ST401闪烁体相对灵敏度随入射γ射线能量的变化曲线。实验值与理论计算结果进行了比较,二者在不确定度范围内基本一致。 The energy sensitivities of a current detector made up of ST401 plastic scintillator widely used in the field of pulse gamma rays measurements were studied experimentally. By means of pulse reactor and accelerator, a series of gamma rays with single or quasi-single energy were produced for calibration. The detector was calibrated by thirteen gamma energies including 137 Cs and 6o Co. The curve of relative energy sensitivities of the detector to incident gamma rays was obtained. The experimental result was compared with the theoretical calculation and they are in agreement within uncertainty.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2008年第9期856-860,共5页 Atomic Energy Science and Technology
关键词 ST401闪烁体 电流型探测器 能量灵敏度 反应堆 加速器 准单能γ射线 ST401 plastic scintillator current detector energy sensitivity reactor accelerator quasi-single energy gamma ray
作者简介 王群书(1956-),男,河北高邑人,研究员,硕士,核物理专业
  • 相关文献

参考文献5

二级参考文献4

  • 1Huang Feizeng,Nucl Instr Method.A,1995年,356卷,397页
  • 2Ding Shengyao,Chin J Nucl Phys,1989年,11卷,3期,31页
  • 3Yang jian-lun, et al. Geometry-compensated Scintillator for Low Yield ICF Burn History Measurements,ECLIM2000: ECLIM2000:26th EUROPEAN CONFERENCE ON LASER INTERACTION WITH MATTER. [C]Proceedings of SPIE Vol.4424(2001) [C] 2001 SPIE .0277-786x/01.
  • 4丁声耀,李宇兵,叶宗垣,容超凡,杨晓芸,郑金美,包宗渝,丁锡祥.准单能6—7MeV γ射线参考辐射场的建立和对6.13MeV能点γ探测效率的绝对刻度[J].原子能科学技术,1992,26(6):9-16. 被引量:6