期刊文献+

电站锅炉过热器壁温的改进计算方法

Improved Method for the Wall Temperature Calculating of Utility Boiler Superheater on Power Plant
在线阅读 下载PDF
导出
摘要 建立了锅炉过热器流量分配的非线性数学模型。该模型的经验参数较少,具有较高的计算精度,并且可以求出管子中工质流量。此方法克服了目前常用的电站锅炉壁温计算方法中校核点工质流量与热负荷并不一定互相对应的缺点。针对蒲城电厂330 MW塔式燃煤直流锅炉过热器1的改造方案,利用提出的方法计算了100%与50%锅炉运行负荷下危险部位的壁温,结果表明,所有校核点的壁温都小于管材最高允许温度,计算方法是可行的。 A nonlinear mathematical model is developed to determine the flow rate distribution in the parallel pipes of boiler superheater. Compared with the flow calculation model presently used by boiler manu factures, the proposed one introduces fewer experience parameters, which may result in higher accuracy. Also, flow rate in each pipe can be obtained. This method avoids the non correspondence between the flow rate and heat flux, which may exists in that used presently. It is employed to calculate the pipe temperature of dangerous position that concerns with the retrofit scheme of superheater 1 of tower type coal-fired 330-MW once-through boiler in Pucheng Power Plant for 100% and 50%operation load.
作者 高杰
出处 《黑龙江水专学报》 2008年第2期63-65,共3页 Journal of Heilongjiang Hydraulic Engineering College
关键词 电站锅炉 过热器壁温 计算方法 utility boiler superheater wall temperature calculation method
作者简介 高杰(1975-),男,江苏扬州人,工程师,硕士,研究方向为热能动力。