期刊文献+

偶氮胂Ⅲ的电喷雾质谱行为 被引量:1

Multiple Stage Electrospray Ionization Mass Spectrometry of Arsenazo Ⅲ
在线阅读 下载PDF
导出
摘要 采用电喷雾质谱法研究了偶氮胂Ⅲ离子化过程。结果发现,偶氮胂Ⅲ易于在电喷雾电离过程中通过去质子化作用形成带有单电荷或双电荷负离子。考察了酸度和醋酸根等离子对偶氮胂Ⅲ电喷雾电离的影响。结果表明,偶氮胂Ⅲ在弱酸性条件下有利于形成负离子。提出了偶氮胂Ⅲ在电喷雾电离源中通过去质子化作用形成负离子的可能机理,并用串联质谱法研究了所形成不同价态离子的裂解规律。结果表明,电喷雾串联质谱法能方便快捷地研究偶氮胂Ⅲ的电离行为和所形成不同价态离子的性质,其检测限达0.74×10-15g。 Electron spray ionization mass spectrometry (ESI-MS) was employed for direct investigation of arsenazo Ⅲ aqueous solutions. Experimentally, it was found that arsenazo Ⅲ formed singly (m/z 775 ) or doubly charged ions( m/z 387) by deprotonation in the ESI process. Under the experimental conditions, the signal of m/z 387 was 20 times higher than that of m/z 775. The formation of the negative ions of arsenazo Ⅲ was favored in weakly acidic solution. The characteristic fragmentation patterns of the anions( i. e. , m/z 775, m/z 387) of arsenazo Ⅲ were obtained by multiple stage tandem mass spectrometry with a collision energy of 15% -25%, providing evidence for identifying arsenazo Ⅲ in a complex mixture. The data showed that a low limit detection of 0. 74 × 10^-15 g was obtained with tandem mass spectrometry for the doubly charged anions (m/z 387 ), showing that electrospray ionization tandem mass spectrometry is a useful tool for the study and detection of arsenazo Ⅲ.
出处 《应用化学》 CAS CSCD 北大核心 2008年第5期510-513,共4页 Chinese Journal of Applied Chemistry
基金 国家自然科学基金(20505003) 国家科技部公益基金(2005DIB6J232)资助项目
关键词 偶氮胂Ⅲ 电喷雾 串联质谱 arsenazo Ⅲ, EsI, tandem mass spectrometry
作者简介 通讯联系人:陈焕文,男,博士,教授;E-mail:chw8868@gmail.com;研究方向:分析化学
  • 相关文献

参考文献11

  • 1Dvornikov A S, Rentzepis P M. Opt Commun[ J], 1997,136( 1,2) :1
  • 2ZHANGXie(张燮),Chief-Edr(主编).Industrial Analysis Chemistry(工业分析化学)[M].Beijing(北京):Chemical Industry Press(化学工业出版社),2003
  • 3Pramanik B N,Gross M L,Ganguly A,Chief-Edr(主编).JIANGHong-Jian(蒋宏健),YuKe-Jia(俞克佳)Trans(译).Aapplied Electrospray Mass Spectrometry(电喷雾质谱应用技术)[M].Beijing(北京):Chemical Industry Press(化学工业出版社),2005:142
  • 4SUNJia-Yan(孙嘉彦),YINYou-Lin(殷有林).Chemical Analysis of Uranothorite (铀钍矿石的化学分析)[M].Beijing(北京):Nuclear Energy Press(原子能出版社),1986:45
  • 5Reichardt C,Auth(著). Solvent Effects in Organic Chemistry(有机化学中的溶剂效应)[M].Beijing(北京):Chemieal Industry Press(化学工业出版社),1978:70
  • 6Michael Mueller. Fundamentals of Quantum Chemistry-Molecular Spectroscopy and Modem Electronic Structure Computations [ M ]. Kluwer Academic Publishers,New York,2002
  • 7McLafferty F W. Interpretation of Mass Spectra[ M ] ,3rd Ed. California:University Science Books, 1980
  • 8成海平,钱小红.蛋白质组研究的技术体系及其进展[J].生物化学与生物物理进展,2000,27(6):584-588. 被引量:52
  • 9张天幕.电喷雾电离质谱及其在蛋白质化学研究中的应用[J].生命科学仪器,2004,2(5):21-25. 被引量:7
  • 10Andreas Dreuw Lorenz S. Phys Rev[J] ,2002:102

二级参考文献37

  • 1[1]Chapman S. Physical Review. 1937, 10: 184~ 190.
  • 2[2]Dole M, Mack L L, Hines R L. Journal of Chemical Physics. 1968, 49:2240 ~ 2249.
  • 3[3]Mack L L, Kralik, P.; Rheude, A.; Dole, M.; Journal of Chemical Physics. 1970, 52:4977 ~ 4986.
  • 4[4]Yamashita M, Fenn J B. Journal of Physical Chemistry.1984, 88:4451 ~ 4459.
  • 5[5]Meng C K, Mann M, Fenn J B. Zeitschrift f ü r Physik D.1988, 10:361 ~ 368.
  • 6[6]Fenn J B, Mann M, Meng C K, et al. Science. 1989, 246:64 ~ 71.
  • 7[7]Bruins A P, Covey T C, Henion J D. Ion Spray Interface for Combined Liquid Chromatography/Atmospheric Pressure Ionization Mass Spectrometry. Anal. Chem. 1987,59:2642 ~ 2646.
  • 8[8]Schneider B B, Douglas D J, Chen D D Y. An Atmospheric Pressure Ion Lens to Improve Electrospray Ionization at Low Solution Flow-Rates. Rapid Commun. Mass Spectrom. 2001, 15:2168 ~ 2175.
  • 9[9]Janiszewski J S, Rogers K J, Whalen K M, et al. A HighCapacity LC/MS System for the Bioanalysis of Samples Generated from Plate-Based Metabolic Screening. Anal.Chem. 2001, 73:1495 ~ 1501.
  • 10[10]Whitehouse C M, Dreyer R N, Yamashita M, et al.Electrospray Interface for Liquid Chromatographs and Mass Spectrometers. Anal. Chem. 1985, 57:675 ~ 679.

共引文献57

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部