摘要 目的探讨Tecnis多焦点人工晶体植入术后早期临床疗效。方法将2006年10月至2007年1月行超声乳化吸出并Tecnis多焦点人工晶体植入术的白内障患者10例为实验组,和同一时期植入的Sensar单焦点人工晶体植入术的白内障患者10例为对照组。检查患者术后裸眼视力及近视力、矫正视力及近视力、术后屈光状态、视野、UBM检查,术后阅读戴镜率。随访时间至术后3个月。结果术后3个月实验组裸眼视力≥0.8者10眼:≥1.0者9眼,与对照组比较差异无统计学意义(P〉0.1)。实验组裸眼近视力≥J3者9只眼:Jl者7眼。实验组与对照组比较差异有统计学意义(P〈0.01)。术后3个月实验组未发现人工晶体位置不对称。实验组20%戴镜阅读,对照组100%戴镜阅渎。结论Tecnis多焦点人工晶体植入术可以提供良好的裸眼远视力及近视力。手术安全可靠,术后未见与之相关的并发症产生。 Objective To evaluate the visual outcome ofTecnis multifocal intraocular lens Methods 10 eyes in 10 patients received phaco and IOL implantation were as test group, 10 eyes(Tecnis multifocal IOL) and case control group 10 eyes(momofocal Sensar IOL),Postoperative examination included distance and near, uncorrected and corrected visual acuity,refractive results,vision field,UBM examination,the rate of wearing spectacles and the complications. Follow-up period ranged to three months. Results 3m after surgery, 100% eyes(10/10) in test group with Tecnis IOL had a distance visual acuity ≥ 0.8,and in 90%(9/10) ≥ 1.0,the differ- ence was not significant(p〉0.1).90% eyes (9/10)in test group had an uncorrected near acuity ≥ J3 and 70%(7/ 10)J1.The difference was significant(p〈0.01 ). The rate of wearing spectacles was 10% in test group and 100% in case control group. Conclusion The implantation of Tecnis IOL not only has a good distance uncorrected visual acuity.but also with better near visual acuity,The surgery is safe,reliable and no special complication induced.
作者 雷晓军 邵彦
出处 《中国实用眼科杂志》 CSCD 北大核心 2007年第12期1304-1306,共3页 Chinese Journal of Practical Ophthalmology
关键词 Tecnis多焦点人工晶体 老年性白内障 人工晶体 tecnis IOL cataract treatment outcome
作者简介 通讯作者:雷晓军 Emial:leixj76@163.com
  • 相关文献

参考文献5

  • 1Mark Packer,MD,I,Howard Fire,MD.Richard S.Hoffman, MD.Patricia. Improved functional vision with a modified prolate intraocular lens. J Cataract Refract Surg, 2004, 30 986-992.
  • 2Roberto Bellucci,MD, Antonio Sxialdone,MD, LucioBuratto,MD, Visual acuity and contrast sensitivity comparision between Tecnis and AcrySof SA60ATintraocular lenses: A multicenter and randomized study: J Cataract Refract Surg,2005,31:712-717.
  • 3李霞,谭少健,梁皓,李伟均,苗重会.多焦点人工晶体眼视功能的研究[J].中国实用眼科杂志,2005,23(1):39-44. 被引量:34
  • 4许维强等.Chin J Pract Ophthalmol.February2005,Vol23,No.2.134-135.
  • 5Wemer W.Hutz,MD. J Cataract Refract Surg,Vol32,december, 2006, 32:2015-2017.

二级参考文献16

  • 1王海林,关家璓,凡长春,陶军.人工晶体位置及类型与伪调节的关系[J].中国实用眼科杂志,1995,13(5):284-286. 被引量:9
  • 2Lim JI, Kuppermann BD, Gwon A, et al. Vitrenretinal surgery through multifocal intraocular lenses compared with monofocal intraocular lenses in fluid - Pilled and air - filled rabbit eyes. Ophthalmology, 2000, 107 (6) : 1083 - 1088.
  • 3Keates RH, Pearce JL, Schneider RT. Clinical results of the multifocal lens. J Cataract Refract Surg, 1987, 13 (5) : 557--560.
  • 4Pieh S, Weghaupt H, Skorpik C. Contrast sensitivity and glare disability with diffractive and refractivemultifocal intraocular lenses. J Cataract Refract Surg, 1998, 24 (5): 659--662.
  • 5Ravalico G. Parentin F, Sirotti P, et al. Analysis of light energy distribution by multifocal intraocular lenses throughan experimental optical model. J Cataract Refract Surg, 1998, 24 (5): 647 652.
  • 6Steinert RF, Aker BL, Trentacost Dj, et al. A prospective comparative study of the AMO ARRAY zonal - progressive multifocal intraocular lens and a monofocal intraocular lens. Ophthalmology, 1999, 106 (7): 1243--1255.
  • 7Dick HB, Krist R, Schwenn O, et al. Near vision after implantation of monofocal versus multifocal intraocular lenses. Kiln Monatsbl Augenheilkd, 2001, 218 (6): 406--411.
  • 8Walkow L, Klemen UM. Patient satisfaction after implantation of diffractive designed multifocal intraocular lenses in dependence on objective parameters. Grades Arch Clin Exp Ophthalmol, 2001,239 (9): 683--687.
  • 9Walkow T. Liekfeld A. Anders N. et al. A prospective evaluation of a diffractive versus a refractive designed multifocal intraocularlens. Ophthalmology. 1997, 104 (9): 1380--1386.
  • 10Kamlesh, Dadeya S, Kaushik S. Contrast sensitivity and depth of focus with aspheric multifocal versus conventional monofocal intraocular lens. Can J Ophthalmol, 2001, 36 (4): 197--201.

共引文献33

同被引文献68

引证文献5

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部