期刊文献+

磁共振弥散张量成像在诊断脑膜瘤和胶质瘤中的应用研究 被引量:1

在线阅读 下载PDF
导出
摘要 磁共振弥散张量成像(diffusion tensor imaging,DTI)是最近几年逐步发展起来的一种水成像技术,是通过各项异性分数(fractional anisotropy,FA)和表观弥散系数(apparent diffusion coefficient,ADC)测量值定量反映脑白质纤维束的损伤程度和完整性,正确地判断肿瘤与白质纤维束的关系,鉴别脑肿瘤的良恶性,给临床治疗和预后提供有价值的信息。
出处 《实用临床医学(江西)》 CAS 2007年第11期132-134,共3页 Practical Clinical Medicine
  • 相关文献

参考文献20

  • 1Peayer D, Prayer L. Diffusion-weighted Magnetic Resonance Imaging of Cerebral white Matter Development[J].Eur J Radiol,2003,45(3) :235-243.
  • 2Bammer R. Basic Principles of Diffusion2 Weighted Imaging[J]. Eur J Radiol,2003,45:169-184.
  • 3Filippi C G,Edgar M A,Ulug A M,et al. Appearance of Meningiomas on Diffusion Weighted Imaging: Diffusion Constants with Histopathologic Findings[J]. AJNR,2001,22( 1 ) :65-72.
  • 4陈星荣,沈天真,耿道颖,梁宗辉.脑膜瘤[J].中国医学计算机成像杂志,2003,9(3):147-190. 被引量:55
  • 5张辉,贺业新,苏晋生,刘起旺,杨晓棠,祁建军.磁共振弥散张量成像在脑膜瘤诊断中的应用价值[J].中国医学影像技术,2005,21(12):1806-1809. 被引量:9
  • 6Price S J ,Burnet N G,Donovan T,et al. Diffusion Tensor Imaging of Brain Tumours at 3T:a Potential Tool for Assessingwhitematter Tract Invasion?[J]. Clin Radiol, 2003,58:455- 462.
  • 7张卫东,梁碧玲,黄穗乔,叶瑞心.脑星形细胞瘤弥散张量成像的初步研究[J].癌症,2004,23(3):317-321. 被引量:23
  • 8Sinha S,Bastin M E,Whittle I R, et al; Diffusion Tensor MR Imaging of High-grade Cerebral Gliomas[J].AJNR, 2002,23 : 520-527.
  • 9Inoue T,Ogasawara K,Beppu T,et al. Diffusion Tensor Imaging for Preoperative Evaluation of Tumor Grade in Gliomas[J]. Clin Neurol Neurosurg, 2005,107 : 174-180.
  • 10史瑞华,漆剑频,王承缘.扩散张量成像在颅内占位性病变中的应用研究[J].中国临床医学影像杂志,2005,16(2):61-63. 被引量:10

二级参考文献51

  • 1Pajevic S, Pierpaoli C.Color schemes to represent the orientation of anisotropic tissues from diffusion tensor data: application to white matter fiber tract mapping in the human brain. Magn Reson Med, 2000, 43(6) :921.
  • 2Jones DK, Horsfield MA, Simmons A. Optimal strategies for measuring diffusion in anisotropie systems by magnetie resonance imaging. Magn Reson Med, 1999, 42(3) : 515-525.
  • 3Elshafiey I, Bilgen M, He R, et al. In vivo diffusion tensor imaging of rat :spinal cord at 7 T. Magn Reson Imaging, 2002,20(3) : 243-247.
  • 4Gulani V, Webb AG,, Duncan ID, et al. Apparent diffusion tensor measurements in myelin - deficient rat spinal cords. Magn Reson Med, 2001, 45(2) : 191-195.
  • 5Murphy BP, Zientara GP, Huppi PS, et al. Line scan diffusion tensor MRI of the cervical spinal cord in preterm infants.J Magn Reson Imaging, 2001, 13(6) : 949-953.
  • 6Van Donkelaar CC, Kretzers LJ, Bovendeerd PH, et al. Diffusion tensor imaging in biomechanical studies of skeletal muscle function. J Anat, 1999, 194( Pt 1) : 79-88.
  • 7Gullberg GT, Defrise M, Panin VY, et al. Efficient cardiac diffusion tensor MRI by three - dimensional reconstruction of solenoidal tensor fields. Magn Reson Imaging, 2001, 19(2):233-256.
  • 8Moseley ME, de Crespigny A, Chew WM. Diffusion/perfusion magnetic resonance imaging. Neuroimaging Clin North Am,1992, 2(4) : 693.
  • 9Moseley ME, Butts K. Diffusion and perfusion. In: Stark DB,eds. Magnetic resonance imaging. 3rd ed, St Louis : CV Mosby,1999, 3:1515-1538.
  • 10Le Bihan D, Breton E, Lallemand D, et al. MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorder,s. Radiology, 1986, 161(2) : 401-407.

共引文献104

同被引文献13

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题