土壤含水率测定的误差分析及控制 被引量:18

Analysis and Control of Errors in Soil Water Content Rate Determination
在线阅读 下载PDF
导出
摘要 土壤湿度空间变异性和样本容量决定了其测定的误差范围和精度。通过样本容量各为15的各层次土壤含水率的统计分析,得到了1m土层各层次的土壤含水率的变异特征。找出了样本容量与测试精度要求及统计特征值的关系。指出,过少的样本容量无法达到研究所需的精度要求。一般最少要5~8个以上的样本容量方可将测试的相对误差控制在5%~10%以下。 The space variations of soil moisture and sample contents are decisive factors to the error ranges and accuracies of the determination. With the statistic analysis of different soil water content rates in samples with the content of 15, the variation characteristics of different soil water content rates at 1 m soil layer are obtained.And the relationship between the sample content, and the measurement accuracy requirement and characteristic value is found out. Also this paper points out that limited numbers of sample contents can't meet the accuracy requirements in research. In general, at least 5~8 sample contents can possibly keep the relative error of the measurement under 5%~10%.
机构地区 西北农业大学
出处 《干旱地区农业研究》 CSCD 北大核心 1997年第2期84-88,共5页 Agricultural Research in the Arid Areas
基金 国家科技攻关项目
关键词 土壤含水率 误差 统计分析 测定 soil water content rate, determination error, statistic analysis