期刊文献+

泵站出水流道的优化试验 被引量:8

Study on the optimum test of pumping station outlet
在线阅读 下载PDF
导出
摘要 为了对箱涵式出水流道的水力特性有更深入的认识,对在建工程伯渎港泵站出水流道进行了较为全面的试验研究。从改善流道流态,降低水力损失的角度出发,采用模型试验和数值计算相结合的方法,对出水流道的喇叭口到流道顶的悬空高、后壁型线和后壁距等主要特征参数进行了多组试验。试验结果验证了出水流道设计的合理性;并发现出水流道悬空高过大或过小均不合适,后壁型线以采用对称蜗壳型式为好,后壁距适当减小是可行的;同时还发现了流道中旋涡产生的位置,分析了产生这些现象的原因。由于采用了两种方法进行对比试验,所以保证了结果的可信性。 In order to have a deeper understanding of hydraulic properties of the box outlet, research and experiments have been done about the Bodugang Pumping Station's outlet. By adjusting flow pattern and reducing the hydraulic loss, model test and numerical simulation were conducted to optimize the hanging depth, the shape of outlet rearward and the distance between the outlet rearward and pumping axis. The results show that the design of outlet is reasonable. The hanging depth is unreasonable if bigger or smaller. The shape of outlet rearward should adopt the symmetrical spiral case. The site of whirlpool in the outlet is determined and the causes of the phenomena are analyzed.
出处 《排灌机械》 2007年第4期30-33,共4页 Drainage and Irrigation Machinery
基金 江苏省高校自然科学基础研究项目(06KJB470126)
关键词 出水流道 模型试验 流态 水力损失 outlet passage model test flow pattern hydraulic loss
作者简介 李大亮(1977-),男,江苏赣榆人,工程师,主要从事泵站设计方面的研究。 张晓芳(1973-),男,江苏丹阳人,工程师,主要从事水工结构方面的研究。
  • 相关文献

参考文献3

  • 1江苏机电排灌工程研究所.泰州引江河工程高港枢纽泵站泵装置模型试验研究报告[R].扬州:江苏机电排灌工程研究所,1996:15.
  • 2顾美娟,卜舸,陆林广,陈阿萍,黄金军.刘老涧二站虹吸式出水流道的优化水力设计[J].排灌机械,2007,25(2):37-39. 被引量:6
  • 3Rodi W.Turbulance model and their application in hydraulics[M].Delft:Section on Fundamentals of Division Ⅱ,1980:44-46.

二级参考文献4

共引文献5

同被引文献31

引证文献8

二级引证文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部