期刊文献+

韶关发电厂W形火焰锅炉二次风道数值模拟计算研究 被引量:4

Numerical Simulation Research for Secondary Air Duct of W-fired Boiler in Shaoguan Power Plant
在线阅读 下载PDF
导出
摘要 应用Fluent数值模拟计算软件对韶关发电厂300MW机组W形火焰锅炉的二次风道进行了计算分析。通过对二次风道的4个工况的模拟计算,找出前后墙风量偏差的原因,提出结构优化的方法,使前后墙风量合理分配,稳定了锅炉的燃烧工况。 By use of numerical simulation calculating software of Fluent, the secondary air duct of a 300 MW unit's W-fired boiler in Shaoguan Power Plant is computed and analyzed. Through analog computation of four conditions of the secondary air duct, the reasons of air quantity difference between the front wall and the rear wall are found out. The method of structure optimization is put forth, so that the air quantity between the front wall and the rear wall is distributed in reason, and the burning conditions of the boiler are stabilized.
作者 王丽娟
机构地区 韶关发电厂
出处 《广东电力》 2007年第4期25-28,42,共5页 Guangdong Electric Power
关键词 W形火焰锅炉 二次风道 风量偏差 数值模拟 W-fired boiler secondary air duct air quantity difference numerical simulation
作者简介 王丽娟(1978-),女,新疆昌吉人。工学硕士,原从事锅炉运行方面的技术工作,现从事电力市场方面的技术管理工作。Tel:0751-6638459,E-mail:wljuan@sgpp.com.cn。