摘要
介绍某电厂取排水口模型试验方案和试验方法。通过模型试验,提出了合理的排水口布置形式,并对其进行了优化。同时,研究了电厂排水对厂区附近局部水域环境温升和对环境流场的影响。研究结果可为对环境影响的评价提供依据。
The testing scheme and testing method of water intake and outlet model for one power plant have been presented. Through the model test, a reasonable water outlet layout pattern has been put forward, and the layout pattern being optimized. At the same time, the influence of water outlet from the power plant upon the ambient temperature rise of local water area near the plant site and upon the ambient flow field has been studied. The results of study provide with basis for evaluation of the environmental influence.
出处
《热力发电》
CAS
北大核心
2007年第2期57-59,62,共4页
Thermal Power Generation
关键词
600
MW机组
冷却水
取水口
排水口
环境流场
600 MW unit
cooling water
water intake
water outlet
ambient flow field
作者简介
张世宝(1966-),男,华北水利水电学院副教授,主要从事水工结构模型工程的教学与研究。E-mail:zhangshibao@ncwu.edu.cn