摘要
通过对影响氨水吸收式制冷循环因素的定性和定量分析,了解这些因素变化如何影响制冷循环的COP值,以及如何控制这些因素的变化使制冷循环的COP值达到最大;并指出完全回收制冷循环的精馏热可使循环的COP值有较大幅度的提高.
By analysing the variation of factors which affect ammonia water absorption refrigeration cycle's COP , how to affect the cycle's COP due to the variation of the factors and how to control these factors to make the cycle's COP higher are known. That the cycle's COP can be increased largely by retrieving the fractional distilation heat is pointed out. The results obtained can help to design the refrigeration system.
出处
《大连理工大学学报》
CAS
CSCD
北大核心
1996年第4期445-450,共6页
Journal of Dalian University of Technology
基金
国家自然科学基金