期刊文献+

A Heavy Metal Analysis Device Based on Light-addressable Potentiometric Sensor

A Heavy Metal Analysis Device Based on Light-addressable Potentiometric Sensor
在线阅读 下载PDF
导出
摘要 <正>A full automatic device to detect heavy metal Hg,Fe,Cr elements based on thin-film sensitive materials prepared on surface of light-addressable potentiometric sensors (LAPS) by means of pulsed laser deposition PLD) technique is developed. High-purity chemical compound AgI:Ag_2S:HgI synthesized were used as target of PLD,thin film sensitive to Hg~ (2+) ion was prepared on the surface of LAPS.All-solide-state chalcogenide glass ion-selective electrodes ISE) ,Fe-ISE and Cr-ISE,were also used as targets of PLD,and thin-film sensors on different LAPS sensitive to Fe~ (3+) and Cr~ (6+) ions were prepared.The heavy metal analysis device with characteristics of collect sample in-site,real-time determination,communication and multifunction software were designed.Hardware design of the device mainly includes control and measurement aspects.The detected limits of Hg,Fe,Cr ions are 3.44×10~ (-7) mol/L,6.31×10~ (-6) mol/L and 2.09×10~ (-7) mol/L,respectively. A full automatic device to detect heavy metal Hg, Fe, Cr elements based on thin-film sensitive materials prepared on surface of light-addressable potentiometric sensors (LAPS) by means of pulsed laser deposition (PLD) technique is developed. High-purity chemical compound AgI:Ag2S:HgI synthesized were used as target of PLD, thin film sensitive to Hg^2+ ion was prepared on the surface of LAPS. All-solide-state chaleogenide glass ion-selective electrodes (ISE), Fe-ISE and Cr-ISE, were also used as targets of PLD, and thin-film sensors on different LAPS sensitive to Fe^3+ and Cr^6+ ions were prepared. The heavy metal analysis device with characteristics of collect sample in-site, real-time determination, communication and multifunction software were designed. Hardware design of the device mainly includes control and measurement aspects. The detected limits of Hg, Fe, Cr ions are 3.44×10^-7 mol/L, 6.31 × 10^-6 mol/L and 2.09× 10^-7 mol/L, respectively.
出处 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期230-231,共2页 Rare Metal Materials and Engineering
关键词 analysis chemistry SENSOR heavy metal LAPS PLD analysis chemistry sensor heavy metal LAPS PLD
作者简介 Email: menhong_china@hotmail.com
  • 相关文献

参考文献4

  • 1Bond A M. Analytic Chimica Acta [J], 1999, (400): 333.
  • 2Aehterberg E P, Braungardt C. Analytic Chimica Acta [J], 1999, (400): 381.
  • 3Hafeman D G, Parce J W, McConnell H M. Science [J], 1988, (240): 1182.
  • 4Mourzina Y, Yoshinobu T, Shubert J et al. Sensors and Actuators B [J], 2001, (80): 136.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部