                    针对研发的军用便携式检定仪计量校准的需求,设计了校准量值的传递与保证方案,提出一种基于固定优先级的自动校准算法.该算法中,占用相同校准资源的校准任务按优先级执行,占用不同校准资源的校准任务则并行执行,充分利用了校准资源.通过以太网接口进行数据通讯,设计了自动校准程序,实现了便携式检定仪自动化校准.
                
                A project of quality value transfer and assurance is designed and an automatic calibration algorithm based on fixed priority is proposed according to the calibration demand on military portable test instrument. In the algorithm, the calibration tasks with the same calibration instruments are executed in term of the priority and the other calibration tasks are executed parallel. Therefore, the calibration instruments are sufficiently utilized. The automatic calibration program is designed and the calibration data is transmitted by Ethernet. The automatic calibration of portable test instrument is realized.
    
    
    
    