摘要 在0.5mol/L硝酸介质中,砷(Ⅴ)能与钼酸铵形成砷钼杂多酸,在表面活性剂聚乙烯醇(PVA)存在下,砷钼杂多酸可以和乙基罗丹明B(ERB)生成可溶于水的络合物,该络合物在605nm处有最大吸收,据此建立了流动注射分光光度法直接测定地表水中砷(Ⅴ)的方法。砷(Ⅴ)在1.0~100μg/L质量浓度范围内符合比尔定律,检出限为0.1μg/L,平行测定40μg/L砷(Ⅴ)14次,相对标准偏差为3.06%。方法用于实际水样分析,回收率在92.6%~105.1%之间,测定结果与原子吸收光谱法基本一致。 It is found that in 0.5 mol/L nitric acid medium arsenic(Ⅴ) reacts with ammonium molybdate to form heteromolybdoarsenic acid,which forms a soluble complex with ethyl rhodamine B in the presence of polyvinyl alcohol(PVA). The complex has maximum absorption at 605 nm. Beer's law is obeyed in the concentration range of 1.0-100μg/L for arsenic(Ⅴ).Based on this, a new flow injection spectrophotometric method for the determination of trace arsenic in surface water was proposed. The relative standard deviation of 3.06 % was obtained by injecting 40μg/L of As(Ⅴ) standard solution( n=14). The detection limit calculated from three times of the average background noise was 0.1μg/L. The recoveries of surface water samples were between 92.6% and 105.1%, and the determination results were in good agreement with those obtained by AAS.
出处 《冶金分析》 CAS CSCD 北大核心 2006年第3期44-46,共3页 Metallurgical Analysis
基金 国家863项目(2002AA639290)
关键词 流动注射分光光度法 砷钼杂多酸 乙基罗丹明B arsenic flow injection spectrophotometry heteromolybdoarsenic acid ethyl rhodamine B
作者简介 陈国和(1974-),男,在读博士,研究方向为现代分离分析技术 通讯联系人:张新申,男,教授,博士生导师,Tel:028-85407553,E-mail:zhangxinshen@126.com。
  • 相关文献

参考文献14

二级参考文献38

共引文献105

同被引文献116

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部