期刊文献+

微型种植钉的长度直径对生物力学的影响 被引量:9

Influence of Mini-screw Diameters and Lengths on Biomechanical Characterizatins of Osseointegration
原文传递
导出
摘要 目的 对比评价临床常用的3种类型(不同长度、直径)微型种植钉的生物力学特点。方法 应用种植钉48枚,新西兰大白兔8只。采用拉出试验,扭转强度试验,在即刻与愈合4周后进行生物力学测量。结果 长度为6mm,直径为1.9mm的种植钉相对于同等长度,直径为1.5mm的种植钉在“种植后即刻”与“愈合4周”时,最大剪切力均表现出显著性优势。愈合4周后,直径为1.9mm的种植体在最大扭转强度上表现出显著性的优势。结论 在骨质量较差的部位选择较大直径的种植体有利于种植体的稳定。 Objective The aim of this in vivo study was to compare biomechanical characteristics of 3 types of commonly used mini- screws with different diameter and/or length. Methods Forty-eight titanium mini-screws were used in this study. A total of 8 New Zealand White rabbits were randomly divided into 2 groups with different healing time. At different time points, the reverse torque and pull-out load were measured. Results Mini-screws with a diameter of 1.9 mm showed significantly greater maximal pull-out load than those with a diameter of 1.5 mm after immediate insertion or 4 weeks of healing and also showed signifcantly greater maximal torque after 4 weeks of healing. Conclusions Mini-screws with a greater diameter were more stable, suggesting that wider implants may be used clinically to increase implant stability.
出处 《口腔正畸学》 2006年第2期53-55,共3页 Chinese Journal of Orthodontics
关键词 种植体支抗 微型种植钉 骨整合 生物力学 implant anchorage, mini-screw, osseointegration biomechanics
  • 相关文献

参考文献7

  • 1张铁,马轩祥,张少锋,姚月玲.种植体直径和长度对支持组织应力分布的影响[J].实用口腔医学杂志,1999,15(3):228-229. 被引量:11
  • 2Block MS.The effect of diameter and length of hydroxyapatite coated dental implants on ultimate pallout force in dog alveolar bone.J Oral MaxilofacSury,1990; 48:174-179.
  • 3Perenyi J.,Bene L.,Radnai M.,et al.Model investigation of push-out test used for quantitative evaluation of dental implatosseointegration.2002 ; 95:105-11.
  • 4Berzins A.,Shah B.,Weinans H.,et al.Nondestructive measurements of implant-bone interface shear modulus and effects of implant geometry in pull-out tests.J Biomed Mater Res,1997;34:337-340.
  • 5Frost HM.Bone‘ mass’and the‘mechanostat’:a proposal.Anat Rec,1987;219:1-9
  • 6Ivanoff CJ.,Sennerby L.,Johansson C.,et al.Influence of implant diameters on the integration of screw implants.An experimental strdy in rabbits.Int J Oral Maxillofac Surg,1997 ; 26:141-148.
  • 7Mailath G,Stoiber B.,Atzek G.,et al.Bone resorption at the entry of osseointegrated implants-a biomechanical phenomenon:finite element study.Stomatol,1989;86:207-212

二级参考文献2