摘要
利用人工泪液浸泡镜片.模拟蛋白吸附.采用紫外分光光度计在波长280 nm处测试经护理液洗脱的蛋白质的吸光度, 计算蛋白质含量。测试除蛋白护理液对软性角膜接触镜上的蛋白质沉淀的洗脱效果。结果除蛋白含量的测试结果具有重复性。该试验方法可以对除蛋白护理液的洗脱率效果进行评价,但尚需完善.
Objective: Testing the protein-removing effect of the protein-removing care solution on the protein precipitation of the soft contact lenses. Method: Soak the lenses into the artificial-tears to simulate the protein absorption, test the absorbency of cleaned protein at the wavelength of 280 nm by UV spectrophotometer, and compute the percentage of protein. Result: Testing results of the percentage of the cleaned protein are repeatable. Conclusion: This experimental method can be used to evaluate the cleaning effect of the protein-removing care solution, but still needs much improvements.
出处
《中国医疗器械杂志》
CAS
2006年第2期131-133,共3页
Chinese Journal of Medical Instrumentation
关键词
护理液
蛋白质沉淀洗脱率
紫外分光光度计
接触镜
care solution, protein deposit removing rate, UV spectrophotometer, soft contact lense.