期刊文献+

Elaborate calibration procedure for cell irradiation at the CAS-LIBB single-particle microbeam

Elaborate calibration procedure for cell irradiation at the CAS-LIBB single-particle microbeam
在线阅读 下载PDF
导出
摘要 Single-particle microbeam is uniquely capable of precisely delivering a preset number of charged particles to individual cells or sub-cellular targets to be determined in vitro, It is crucial to find a reference point that relates the microbeam's location to the microscope's plane, and align individual targets at this reference point for cell irradiation. To choose an appropriate reference point, an approach based on analysing the intensity distribution of fluorescence in a thin scintillator excited by traversing particles is newly developed using the CAS-LIBB single-particle microbeam, which features decisive physical signification and sufficient resolution. As its bonus, this on-line analysis provides precise and fast response to the determination of beam profile and potentially optimizes the microbeam quality by further adjusting hardware setup. Single-particle microbeam is uniquely capable of precisely delivering a preset number of charged particles to individual cells or sub-cellular targets to be determined in vitro, It is crucial to find a reference point that relates the microbeam's location to the microscope's plane, and align individual targets at this reference point for cell irradiation. To choose an appropriate reference point, an approach based on analysing the intensity distribution of fluorescence in a thin scintillator excited by traversing particles is newly developed using the CAS-LIBB single-particle microbeam, which features decisive physical signification and sufficient resolution. As its bonus, this on-line analysis provides precise and fast response to the determination of beam profile and potentially optimizes the microbeam quality by further adjusting hardware setup.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第4期659-664,共6页 中国物理B(英文版)
关键词 single-particle microbeam calibration procedure cell irradiation targeting accuracy single-particle microbeam, calibration procedure, cell irradiation, targeting accuracy
作者简介 E-mail: zlyu@ipp.ac.cn
  • 相关文献

参考文献19

  • 1Mothersill C and Seymour C B 2004 Nat. Rcv, Cancer 4 158.
  • 2Legge G J F 1997 Nucl, Instrum. Methods B 130 9.
  • 3Folkard M, Prise K M, Vojnovic B, Gilchrist S, Schettino G, Belyakov O V, Ozols A and Michael B D 2001 Nucl.Instrum, Methods B 181 426.
  • 4Folkard M, Vojnovic B, Prise K M and Michael B D 2002 Instrum. Methods B 188 49.
  • 5Brenner D J and Hall E J 2002 Radial. Prot. Dosim. 99 283.
  • 6Folkard M, Vojnovic B, Gilchrist S, Prise K M and Michael B 2003 Nucl. Instrum. Methods B 210 302.
  • 7Hu Z W, Wu L J and Yu Z L 2005 Plasma Sci. Technol.7 2789.
  • 8Hu Z W, Yu Z L, Wu L J, Hu S H and Xu A 2003 Nucl.Instrum. Methods A 507 617.
  • 9Wang X F, Wang X H, Chen L Y and Hu Z W 2004 Chin.Sci, Bull, 49 1806.
  • 10Wang X F, Chen L Y, Hu Z W, Wang X H, Zhang J, LiJ, Chen B, Hu S H, Shi Z T, Wu Y, Xu M L, Wu L J,Wang S H and Yu Z L 2004 Chin, Phys, Lett, 21 821.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部