期刊文献+

Electromagnetic anti-fouling technology for prevention of scale 被引量:2

Electromagnetic anti-fouling technology for prevention of scale
在线阅读 下载PDF
导出
摘要 An electromagnetic anti-fouling technology(EAFT) was developed further. The operating principle of the EAFT was presented using fundamental physics laws. To validate the effect of EAFT and identify the mechanism, a circulating flow setup was built. A series of fouling tests were carried out with and without EAFT, measuring fouling thermal resistance as function of time, making scanning electron microscope images and analyzing the particles size distribution in solution by dynamics light scattering technology. The main results were as follows: 1) All the precipitated crystals in solution were calcite and there were little differences between with EAFT and without EAFT in the experimental range. 2) The number of precipitate nucleation in solution was small and the particle growth was slow without EAFT. In opposition to the case untreated, a rapid particle growth was observed and the number of nucleation was expected to be large, due to the fact that the EAFT effectively increases the ions and crystals collision frequency and effectiveness by utilizing the induced electric field. It is indicated that the particle growth is promoted mainly by coagulation process but not nucleation growth. 3) The EAFT could prolong the delay time of fouling greatly, and after the delay time, the thermal resistance quickly increased. Therefore, in order to mitigate scale significantly, the floccules in solution should be deposited beforehand in a low-lying area of the exchangers and let off in time. An electromagnetic anti-fouling technology(EAFT) was developed further. The operating principle of the EAFT was presented using fundamental physics laws. To validate the effect of EAFT and identify the mechanism, a circulating flow setup was built. A series of fouling tests were carried out with and without EAFT, measuring fouling thermal resistance as function of time, making scanning electron microscope images and analyzing the particles size distribution in solution by dynamics light scattering technology. The main results were as follows: 1) All the precipitated crystals in solution were calcite and there were little differences between with EAFT and without EAFT in the experimental range. 2) The number of precipitate nucleation in solution was small and the particle growth was slow without EAFT. In opposition to the case untreated, a rapid particle growth was observed and the number of nucleation was expected to be large, due to the fact that the EAFT effectively increases the ions and crystals collision frequency and effectiveness by utilizing the induced electric field. It is indicated that the particle growth is promoted mainly by coagulation process but not nucleation growth. 3) The EAFT could prolong the delay time of fouling greatly, and after the delay time, the thermal resistance quickly increased. Therefore, in order to mitigate scale significantly, the floccules in solution should be deposited beforehand in a low-lying area of the exchangers and let off in time.
出处 《Journal of Central South University of Technology》 EI 2006年第1期68-74,共7页 中南工业大学学报(英文版)
基金 Projct(G2000026304)supportedbytheNationalKeyFundamentalResearchandDevelopmentProgramofChina
关键词 electromagnetic anti-fouling calcium carbonate delay time MECHANISM 锅炉 电磁净化 水处理 EAFT 水垢
作者简介 Correspondence:XING Xiao-kai, Associate professor, PhD; Tel:+86-10-89734831; E-mail: xingxk2002@emails. bjut. edu. cn
  • 相关文献

参考文献10

  • 1LeeSungH.AstudyofPhysicalWaterTreatment TechnologytoMitigatetheMineralFoulinginHeat Exchanger[]..2002
  • 2FANChun fu.AStudyofElectronicDescalingTechnol ogytoControlPrecipitationFouling[]..1997
  • 3ChoiBG.AStudyofFoulingControlinHeatEx changerswithElectronicAnti foulingTechnology[]..1998
  • 4MunsonBR,YoungDF,OkiishiTH.Fundamentals ofFluidMechanics[]..1994
  • 5LIURong.AStudyofFoulinginaHeatExchanger withanApplicationofanElectronicAnti fouling Technology[]..1999
  • 6KimWontae.AStudyofPhysicalWaterTreatment MethodsfortheMitigationofMineralFouling[]..2001
  • 7TaborekJ,KnudsenJG,AokiT,etal.Fouling:the majorunresolvedprobleminheattransfer(I):fouling mechanisms,theircharacteristicsandfactorsinfluencing them[].ChemicalEngineeringProgress.1972
  • 8TroupJA.Scalenucleationonaheattransfersurface anditsprevention[].ChemEngComm.1978
  • 9BranchCA,M櫣ller SteinhagenH.Influenceofscal ingontheperformanceofshell and tubeheatexchang ers[].HeatTransferEngineering.1991
  • 10WatkinsonAP,LouisL,BrentR.Scalingofen hancedheatexchangertube[].CanadianJChemEng.1974

同被引文献27

  • 1吴智慧,陈永昌,邢小凯,马重芳.电磁抗垢机理的实验研究[J].水处理技术,2006,32(4):49-52. 被引量:14
  • 2Peyghambarzadeh S M, Vatani A, Jamialahmadi M. Application of asymptotic model for the prediction of fouling rate of calcium sulfate under subcooled flow boiling[J]. Applied Thermal Engineering, 2012, 39:105-113.
  • 3Leonard D T, Book C P, Byung J B, et al. An experimental study on the bulk precipitation mechanism of physical water treatment for the mitigation of mineral fouling[J]. International Communications in Heat and Mass Transfer, 2007, 34: 673-681.
  • 4Cho Y I, Fridman A F, Lee S H, et al. Physical water treatment for fouling prevention in heat exchangers[J]. Advances in Heat Transfer, 2004, 38: 1-72.
  • 5Parsons S A, Judd S J, Stephenson T, et al. Magnetically augmented water treatment[J]. Trans IChemE, 1997, 175: 98-104.
  • 6Donaldson J, Grimes S. Lii~ing the scales from our pipes[J]. New Scientist, 1988, 18: 43-46.
  • 7Smith C, Coetzee P P, Meyer J P. The effectiveness of a magnetic physical water treatment device on scaling in domestic hot-water storage tanks[J]. Water SA, 2003, 29(3): 231-236.
  • 8The U S Department of Energy. Non-chemical technologies for scale and hardness control[M]. Columbus: Thomas Register, 1998: 1-29.
  • 9QUAN Zhenhua, CHEN Yongchang, MA Chongfang, et al. Experimental study on anti-fouling performance in a heat exchanger with low voltage electrolysis treatment[J]. Heat Transfer Engineering, 2009, 30(3): 181-188.
  • 10Ushakov G V. Antiscaling treatment of water by an electric field in heat-supply networks[J]. Thermal Engineering, 2008, 55(7): 570-573.