期刊文献+

运用热脱附/GC/MS分析研究室内空气中TVOC浓度及种类分布 被引量:13

Reseach on total volatility organic compounds(TVOC) in indoor air using thermal desorption/GC/MS technique
在线阅读 下载PDF
导出
摘要 利用热脱附/GC/MS联用技术定性、定量(半定量)分析了多组有代表性的室内空气样品。结果表明,室内空气挥发性有机气体的主要成分是苯系物、烃类、醛酮类、酯类等;装修后3个月内的家居室内空气中的苯25%超标,甲苯58%超标,二甲苯79%超标,TVOC 100%超标;一年后,仅TVOC还有11%的超标。办公室情况类似。 In order to reseach the pollution of Total volatility organic compounds(TVOC) in indoor air, the paper analysis many groups of sample by using the thermal desorption/GC/MS technique through quality , quantity ( semi quantity ) dermination. The result showed that the main kinds of identified VOCs compounds in indoor air are BTEXs, hydrocarbons/aldehydes/-esters, ects. 25 % of benzene, 58 % of toluene,79% of xylene and 100% of TVOC's concentration exceed the nation's standards of indoor air in the houses 'after decorated 3 months. But,in the houses decorated one year only 11% of TVOC's exceed the standards. The results of offices are similarly to the houses.
作者 王玲玲
出处 《中国环境监测》 CAS CSCD 北大核心 2005年第6期7-10,共4页 Environmental Monitoring in China
关键词 热脱附 GC/MS 室内空气 VOCS thermal desorption GC/MS indoor air VOCs
作者简介 王玲玲(1967-),女。河南许昌人,高级工程师.
  • 相关文献

参考文献6

  • 1梁宝生,田仁生.总挥发性有机化合物(TVOC)室内空气质量评价标准的制订[J].重庆环境科学,2003,25(5):1-3. 被引量:55
  • 2国际安全品规划署,欧洲共同体委员会合编.国际化学品安全卡手册(一卷).国家环境保护局组织翻译.北京:化学工业出版社,1995.
  • 3Ma,C.Y, Skeen,J.T, EPATO-1:Triple sorbent thermal desorption/gas chromatography/mass spectrometry determinaton of vapor phase organic contaminants; First Edit,Oak Ridge National Lab.,TN.Department of Energy,Washington,DC Press,1994,4.
  • 4GB/T18883附录C:总挥发性有机物TVOC的检验方法.国家环保局等颁,2002.
  • 5国际安全品规划署,欧洲共同体委员会合编.国际化学品安全卡手册(二卷).国家环境保护局组织翻译.北京:化学工业出版社,1996.
  • 6国际安全品规划署,欧洲共同体委员会合编.国际化学品安全卡手册(三卷).国家环境保护局组织翻译.北京:化学工业出版社,1999.

二级参考文献21

  • 1US-EPA:IAQ a Concern in EPA's Planned 232-Million Research Facility. Indoor Air Qualyity Update 9,1996,10:8-13.
  • 2Helsinki FiSIAQ/Finnish Society of Indoor Air Quality and Climate,Finnish Association of Construction Clients/RAKLI, Finnish Association of Architects/SAFA,Finnish Association of Consulting Firms/SKOL. Classification of Indoor Climate, Construction, and Finishing Materials. 1995.
  • 3EU-ECA-WG13. The use of TVOC as an indicator in IAQ investigations. Report of Working Group 13 of European Collaborative Action on Indoor Air Quality and its Impact on Man.JRC,Ispra ,Italy. 1996.
  • 4WHO: Indoor air quality: organic pollutants. Euro Reports and Studies No. 111. World Health Organization, Regional Office for Europe ,Copenhagen. 1989.
  • 5Mφlhave L. :Indoor air quality in relation to sensory irritation due to volatile organic compounds. ASHRAE Trans., 1986 2954, 92(1) ,1-12.
  • 6ENV Ministry of the Environment. Singapore Guidelines for good indoor air quality in office premises, Singapore, 1996.
  • 7EHS Consultants Limited. Final Report : Agreement No. CE 14/95 Consultancy Study on Indoor Air Pollution in Offices and Public Places in Hong Kong.
  • 8Bluyssen P. M. et al. European indoor air quality audit project in 56 office buildings. Indoor Air, 1996,6 : 221-238.
  • 9Brown S. K Assessment and control of volatile organic compounds and house dust mites in Australian buildings. Proceedings of Indoor Air' 96 ,Nagoya,Japan, 1996, (2) :97-102.
  • 10Brown V.M. and Crump D.R. Volatile organic compounds. In:“Indoor Air Quality in Homes: Part 1-The Building Research Establishment Indoor Environment Study”, Building Research Establishment,Watford, 1996,38-66.