期刊文献+

板翅式换热器封头内部流场的测量与改进研究 被引量:9

Particle Image Velocimetry Experimental Investigation of Header Configuration on Flow Maldistribution in Plate-Fin Heat Exchanger
在线阅读 下载PDF
导出
摘要 利用粒子图像测速仪(PIV),对板翅式换热器封头结构改进前、后的流场进行了可视化研究分析.实验结果表明,原始封头内部的物流分配存在严重的不均匀性,采用添加打孔挡板之后的改进型封头,流场的不均匀性有了很大的改善.从实验对比分析中得出,当挡板小孔呈错排分布、开孔率沿挡板的中轴线向两侧逐渐增加、且总开孔率达到50%左右的时候,在相同的入口条件下,不均匀系数由原始封头的1.210降至0.209,最大流速与最小流速之比由23.163降至1.756.此研究结果对于板翅式换热器的优化设计具有重要意义. Flow characteristics of flow field in the header of a plate-fin heat exchanger were inves- tigated with particle image velocimetry (PIV). It is found that the fluid flow maldistribution is very serious for conventional header while the improved header configuration with punched baffle can effectively improve the performance. When the punched baffle is proper in length, the small holes are in staggered arrangement and the punched ratio gradually increases from the central axis to the boundary along the baffle length, the performance of flow distribution in the plate-fin heat exchanger is effectively improved by the optimum design of header configuration. The flow maldistribution parameter S decreases from 1. 210 to 0. 209 and the ratio of the maximum velocity to the minimum decreases from 23. 163 to 1. 756.
出处 《西安交通大学学报》 EI CAS CSCD 北大核心 2006年第1期10-13,共4页 Journal of Xi'an Jiaotong University
基金 教育部跨世纪优秀人才基金资助项目 全国首届优秀博士学位论文作者专项基金资助项目(199933) 西安交通大学博士学位论文基金资助项目(DFXJTU2004-02)
关键词 板翅式换热器 粒子图像测速仪 封头结构 plate-fin heat exchanger particle image velocimetry header configuration
作者简介 文键(1976-),女,博士生;厉彦忠(联系人),男,教授,博士生导师.
  • 相关文献

参考文献6

  • 1Mueller A C, Chiou J P. Review of various types of flow maldistribution in heat exchangers [J]. Heat Transfer Engineering, 1988, 9 (2):36-50.
  • 2J iao A J, Li Y Z,Chen C Z, et al. Experimental investigation on fluid flow maldistribution in platefin heatexchanger[J]. Heat Transfer Engineering, 2003, 24(4):25-31.
  • 3Zhang Zhe, Li Yan Zhong. CFD simulation on inlet configuration of plate-fin heat exchanger[J]. Cryogenics, 2003, 43(12):673-678.
  • 4Wen Jian, Li Yanzhong. Study of flow distribution and its improvement on the header of plate-fin heat exchanger[J]. Cryogenics, 2004,44(11).823-831.
  • 5Weterweel J. Fundamentals of digital particle image velocimetry[J]. Measurement Science and Technology, 1997,8(12):1392-1397.
  • 6Duursma G R,Glass D H,Rix S J L,et al. PIV investigations of flow structures in the fluidised bed freeboard region[J]. Powder Technology, 2001,120(1).2-11.