一种新型中高温热泵混合工质的循环性能 被引量:13

Cycle Performances of a New Mixture for Moderate and High Temperature Heat Pump
在线阅读 下载PDF
导出
摘要 提出了一种新的中高温热泵非共沸混合工质M.新工质ODP为0,GWP较低,输运性能优良,在90℃~110℃的冷凝温度范围,压力水平适中,有5℃~8℃的相变温度滑移,理论循环COP(性能系数)和qv(单位容积制热量)均优于传统工质CFC114.在采用HCFC22空调硬件建立的循环性能实验装置上,实现了正常水流量下冷凝器出水温度达到98℃的实验工况;最高COP达到2.8. A new non-azeotropic mixture was proposed as the working fluid for moderate and high temperature heat pump applications based on theoretical analysis and experimental investigations. The mixture has fair transport properties and greater theoretical Coefficient of Performance (COP) and its volumetric capacity values are greater than those of CFC114. An experimental COP of 2.8 and an outlet water temperature of 98℃ were achieved with the mixture.
出处 《制冷学报》 CAS CSCD 北大核心 2005年第4期35-39,共5页 Journal of Refrigeration
基金 国家自然科学基金资助项目(50476062)
关键词 工程热物理 新型中高温热泵工质 理论循环 实验研究 循环性能 Engineering thermophysics Moderate and high temperature heat pump working fluid Theoretical analysisand experimental investigations
  • 相关文献

参考文献6

  • 1Kazuo Nakatani, Mitsubiro Ikoma, Koji Arita. National Technical Report, 1989, 35(6):12-16.
  • 2Marine Ho..gberg, Thore Berntsson. Non-azeotropic mixtures as working fluids in two-stage economizer- type heat pump. International Journal of Refrigeration, 1994, 17(6): 417-429.
  • 3Navin C Patel,Amyn S Teja. A new cubic equation of state for fluid and fluid mixtures. Chemical Engineering Science,1982,37(3): 463-473.
  • 4Dongsoo Jung, Yongjae Song. Performance des mélanges de frigorigenes utilizes pour remplacer le HCFC22. International Journal of Refrigeration,2000, 23: 466-474.
  • 5Greco, A et al. R407C as an alternative to HCFC22 in vapor compression plant: an experimental study. International Journal of Energy Research,1997, 21(12): 1087-1098.
  • 6李海龙.[D].天津:天津大学,2001.

同被引文献113

引证文献13

二级引证文献89

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部