期刊文献+

福建省年最大降温负荷测算分析与研究 被引量:12

Calculation and analysis of annual maximum temperature-lowering load in Fujian province
原文传递
导出
摘要 对福建省2002~2005年的最大降温负荷进行了测算分析和研究.分析出福建省最大降温负荷主要发生在7~8月的工作日,工作日最大降温负荷高出休息日600 MW左右.工作日最大降温负荷的发生时间由以往的早高峰、午高峰向晚高峰转移,午高峰时的最大降温负荷平均是晚高峰最大降温负荷的80%左右.居民和第三产业的降温负荷占较大的比例.并分析出降温负荷同气象因素之间的关联关系,从而得到人们使用降温设备的一般规律. Calculating and analyzing the maximum temperature-lowering load in Fujian during 2002 to 2005, it is concluded that the maximum temperature-lowering load in Fujian happens mainly in working hours of July and August, and the maximum temperature-lowering load in working hours are about 600 MW higher than that in holidays. What's more, the time when the maximum temperature-lowering load happens are shifting from the usual morning and noon peaks to the evening peak, and on an average, the maximum temperature-lowering load at the noon peak is about 80% of the that at the evening peak. The temperature-lowering load of residents and the tertiary industry account for a large proportion. The relationship between the temperature - lowering load and meteorologic factors are worked out, and the general principles of using temperature-lowering equipment are given.
出处 《华东电力》 北大核心 2005年第10期86-90,共5页 East China Electric Power
关键词 电力负荷 降温负荷 气象因素 最高温度 power load temperature-lowering load meteorologic factor the highest temperature
作者简介 邱向京(1966-),女,高级工程师.主要从事营销管理需求侧管理、市场分析等工作.
  • 相关文献

参考文献2

二级参考文献3

  • 1[1]国家电网公司,中国电力企业联合会.中国电力市场分析与研究[M].北京:中国电力出版社,2003.
  • 2[6]Lee K T, Park J H. Short term load forecasting using an arfficial neural network[J]. IEEE Trans on Power Systems , 1992, 7(1): 124-132.
  • 3[8]赵作善.数值分析[M].北京:北京农业工程大学,1992.

共引文献18

同被引文献112

引证文献12

二级引证文献115

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部