期刊文献+

对高效空气过滤器检漏的研究

Study on Leak Test for HEPA Filters
在线阅读 下载PDF
导出
摘要 过滤器检漏测试是洁净室的洁净和质量的决定性因素之一,因此本文从上游发尘方式的选择,到上游气溶胶粒径分布、上游气溶胶浓度,等几个方面讨论了上游尘源特性对检漏测试的影响,然后又对受上游气溶胶浓度影响的几个参数进行了论述,并且详尽阐述了它们对检漏的重要意义,以及确定原则。并得出了确定漏点所需要的最小尘粒数的取值范围应在4~6之间的结论。 Air filter leakage test is one of the most critical control points of the cleanroom cleanliness and quality. This paper discussed the leak testing influence aroused by the characteristic of the upper stream particulate from the particle size distribution of the upper stream aerosol, the concentration of upper aerosol and so on. Then the paper discussed several parameters that were affected by the concentration of upper stream aerosol, expounded the meaning of the parameters to determine leakage and made sure the principle to these parameters. Finally the paper reached the conclusion that the value range of the expected minimum particle number for a leak should be from 4~6.
出处 《洁净与空调技术》 2005年第3期7-11,共5页 Contamination Control & Air-Conditioning Technology
关键词 高效空气过滤器 检漏测试 洁净室 尘源特性 气溶胶 Aerosol concentration Particle size Scan rate Penetration rate
作者简介 姜军,男,1978年7月生,硕士研究生,助理工程师 518031 深圳市福田区上步南路1001号 锦峰大厦77号信箱
  • 相关文献

参考文献5

  • 1Procedural Standards for Certified Testing of Cleanrooms. Second Edition-1996, NEBB:1996.
  • 2Naoya Nishimura, Shuji Fujii and Kazuhiro Yuasa.Statistical Proposal for Filter Leakage Test, ICCCS, 2000,464-470.
  • 3High efficiency air filters (HEPA and ULPA) BS EN 1822-4:1998.
  • 4IEST-RP-CC006.2: testing cleanrooms, Institute of Environmental Sciences and Technology, 1995.
  • 5Lothar Gail, Dirk Stanischewski. Installed HEPA Filter Leak Testing by Using Discrete Particle CountingInvetigation into Practicability. The IEST annual technical meeting 2002.