摘要
目的为了战时更好地救治伤后官兵,满足官兵伤后对无菌医疗用品的需求,保证一线救治医疗活动的无菌医疗器具供应。方法采取实验调查的方法,掌握高原影响灭菌工作的因素,根据灭菌原理,结合地域特点,提出选用136℃作为高原地区灭菌温度的方法进行实验。结果选用仪表温度示值136℃20 min灭菌方法后,灭菌效果监测达到灭菌效果评价标准,可以满足海拔高度≤5 380 m灭菌条件需求。结论仪表温度示值136℃20 min灭菌,提高了高原地区部队的灭菌工作质量,有利于战时灭菌物品供应,促进了战时卫勤保障能力的提高。
OBJECTIVE To provide sterilization services with national standard in order to meet the need of sterilization for field troops at high altitude,METHODS To study factors which could affect the performance of sterilization at high altitude by way of experimentation with real situation, and to select 136℃ as target temperature. Effectiveness of sterilization was examined. RESULTS Effectiveness of sterilization was up to standard at temperature of 136℃ when altitude≤5380 m. CONCLUSIONS Sterilization at the temperature of 136℃ can effectively improve the sterilization quality at high altitude.
出处
《中华医院感染学杂志》
CAS
CSCD
北大核心
2005年第9期1017-1018,976,共3页
Chinese Journal of Nosocomiology