期刊文献+

灰色关联分析在竖井冻结壁“窗口”事故处理中的应用 被引量:19

Application of grey correlative analysis for disposal of the freezing wall "window" accident
在线阅读 下载PDF
导出
摘要 根据测温孔和冻结器的纵向测温,提出采用灰色关联法进行数据分析.通过孔与孔的关联度计算来评价各冻结器的工作效果,确定薄弱的冻结器方位,然后根据关联度离差和总关联度随深度的变化,确定冻结壁在深度方向的薄弱环节.运用灰色关联分析对竖井冻结壁“窗口”事故实例进行了对照分析,验证了理论的实用性. According to longitude temperature supervision on freeze pipe and monitoring hole, put forward a new method called grey correlative to analyze the temperature data. The working effect of freezing pipe was evaluated by calculating the grey correlative degree (GCD), defined the location of the weaken freeze pipe. Besides, based on the change of deviation squares of GCD and total GCD with the depth, the weaken location of freezing wall was indicated along the shaft. A case of “window” accident of freezing wall was analyzed with GCD method, and the practical value was verified.
出处 《煤炭学报》 EI CAS CSCD 北大核心 2005年第4期467-471,共5页 Journal of China Coal Society
关键词 冻结凿井 关联度 灰色系统 测温 ground freezing shaft sinking correlative degree grey system temperature inspection
作者简介 杨松林(1958-),男,贵州贵阳人,硕士,副教授.Tel:010-51688207,E-mail:slyang@center.nitu.edu.cn
  • 相关文献

参考文献3

  • 1HΓ特鲁巴克 周文安 马光弟 孙辑正 译.冻结凿井法[M].北京:煤炭工业出版社,1958.119-145.
  • 2中国煤炭学会矿井建设委员会.地层冻结工程技术和应用[A]..中国地层冻结工程40周年论文集[C].北京:煤炭工业出版社,1995.199-205.
  • 3周晓敏,张绪忠.冻结器内测温判定冻结壁厚度的研究[J].煤炭学报,2003,28(2):162-166. 被引量:21

二级参考文献3

  • 1中国矿业大学.特殊凿井[M].北京:煤炭工业出版社,1985..
  • 2南京工学院数学教研组.数学物理方程与特殊函数[M].北京:高等教育出版社,2001..
  • 3中国煤炭协会矿井建设委员会.地层冻结工程技术和应用[A]..中国地层冻结工程40周年论文集[C].北京:煤炭工业出版社,1995..

共引文献20

同被引文献152

引证文献19

二级引证文献130

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部