摘要 射频线圈是磁共振成像系统中拾取信号的核心元件。在线圈设计过程中,可以以优化信噪比为目标求解源电流的分布。文中利用磁偶极子的概念,将分布在有限的平面或圆柱面上的电流进行分解,构造基线圈,并引入一个环路基线圈处理圆柱面上的环形电流情况;然后通过源电流分布和基线圈电流分布之间的映射关系,求解使得来自空间某点信号的信噪比最优时的源电流分布。应用这一原理计算了一个源电流分布在圆柱表面上的实例以及工程实际中射频线圈信噪比的物理上限,并讨论如何利用这一结果对线圈的信噪比性能进行评估。 Radio-frequency (RF) coils are used to pick up signals in the magnetic resonance imaging (MRI) systems. This paper presents an inverse design approach of RF coils with arbitrary conductor patterns to optimize the signal-to-noise ratio (SNR) at a point of interest. The source current is assumed to distribute in a specified plane area or a cylinder surface. Based on magnetic dipoles, it can be considered as a weighted current combination of an array of base coils. A single circular loop base coil is added in the array for the cylinder case to emulate the loop currents around cylinder. To achieve the best SNR at a given point in the object, the currents in the base coils are optimized and continuous current density distributions are then derived. By this method, the ultimate intrinsic SNR for various points inside a cylindrical object is estimated, and the method to evaluate the SNR performance of RF coils is discussed.
出处 《中国电机工程学报》 EI CSCD 北大核心 2005年第13期139-143,共5页 Proceedings of the CSEE
关键词 电磁场 逆问题 磁共振成像 射频线圈 信噪比 EMF Inverse problem MRI RF coils SNR
  • 相关文献

参考文献15

  • 1Mark A B, Richard C S. MRI basic principles and applications [M]. NewYork: WileyLiss, 1995.
  • 2E Mark H, Robert W B, Michael R T et al. Magnetic resonance imaging-physical principles and sequence design[M]. New York:Wiley Liss, 1999.
  • 3Jin Jianming. Electromagnetic analysis and design in magnetic resonance imaging[M]. New York: CRC Press, 1998.
  • 4Hubert V, Robert E C. The signal-to-noise ratio of nuclear magnetic resonance surface coils and application to a lossy dielectric cylinder model-part Ⅰ: theory[J]. IEEE Trans. on Biomedical Engineering,1995, 42(5): 497-506.
  • 5Hayes C E. Noise performance of surface coils for magnetic resonance imaging at 1.5T[J]. Medical Physics, 1985, 12(5): 604-607.
  • 6Romeo P, Thomas V, ArunTetal. Performance comparison of S, 16 and 32 column RF birdcage resonators[C]. San Francisco: Nuclear Science Symposium and Medical Imaging Conference Record, IEEE, 1995.
  • 7丁美新,苏中义.磁共振成像鞍型射频线圈的优化设计[J].上海交通大学学报,1996,30(5):103-108. 被引量:4
  • 8BottomleyPA, LugoOCH, RandyG. What is the optimum phased array coil design for cardiac and torso magnetic resonance [J]. Magnetic Resonance in Medicine, 1997, 37(4): 591-599.
  • 9Fujita H, Petropoulos L S, Morich M A et al. A Hybrid Inverse Approach Applied to the Design of Lumped-Element RF Coils [J]. IEEE Trans. on Biomedical Engineering, 1999, 46 (3): 353-361.
  • 10Lawrence B G, Stuart G, Yau D D et al. A time-harmonic inverse methodology for the design of RF coils in MRI[J]. IEEE Trans. on Biomedical Engineering, 2002, 49(9): 1024-1030.