摘要 针对PWM电压型变频器死区时间对输出电压的影响,提出了一种死区时间补偿方案。该方案通过电流矢量空间角判断感应电机三相定子电流正负,推导出三相定子电压的补偿量。实验显示了该方案的有效性。 Aimed at the influence on the inverter output voltage caused by the PWM inverter dead-time, one dead time compensation strategy is proposed. This scheme utilize the current vector space angle to judge the three stator current polarity, deduce the three stator voltage compensations. The experiments demonstrate the validity of the proposed shceme.