摘要
通过实验研究证明了用主流阻尼器快速调节半开口直流式低速风洞的实验风速的可行性。实验还考察了驻室容积、风扇转速等因素对调速加速度的影响,为稳态扫描环境模拟试验装置快速变速系统提供了必要的设计参数。
For a low speed blow down wind tunnel with semi-open test section, the effectiveness of main flow damper in rapidly changing test velocity is verified through experimental research. Influences of plenum volume and fan rotation speed on acceleration are also investigated. The results have been used to design the velocity regulating system for a circumstance simulation facility for steady scanning.
出处
《实验流体力学》
CAS
CSCD
北大核心
2005年第1期56-60,共5页
Journal of Experiments in Fluid Mechanics
关键词
低速风洞
阻尼器
快速调节
实验研究
稳态扫描
low speed wind tunnel
damper
fast regulation
experimental research
steady scan