摘要
对甬-台-温高速公路采用真空-堆载联合预压处理软基前后的土样进行了室内试验分析,得出了合理的试验结论,即土的物理性质指标分别得到不同程度的降低,强度指标得到较大的提高。
An experimental analysis is performed on the project of soft foundation treatment for the Yong-Tai-Wen expessway with vacuum-accumulation loads combined precompression technique, by analysis of the test results in the three different periods during construction, the soil parameters decrease to different extents but of soil strength increases.