Thermal comfort in naturally ventilated indoor environment in hot and humid climate zone in P. R. China

Thermal comfort in naturally ventilated indoor environment in hot and humid climate zone in P. R. China
在线阅读 下载PDF
导出
摘要 To identify human thermal comfort in naturally ventilated buildings,the research based on both subjective and objective data was carried out in Chongqing,P. R. China. The characteristics of subjects' clothing regulation function,changes of actual mean thermal comfort vote (AMV) varying with time and acceptable operative temperature in natural conditions were analyzed. In addition,the indicator actual mean vote-actual percentage dissatisfied (AMV-APD) was used to study the actual dissatisfaction with thermal environment. The results indicate that regulative ability by changing clothing under natural ventilated conditions is very significant but limited simultaneously,about 1.7 ℃ per 0.1 clo. Under naturally ventilated conditions,people may have an acceptable operative temperature of 16-28 ℃. Based on the AMV-APD,the actual minimum percentage dissatisfied can reach 4% at AMV of -0.36. To identify human thermal comfort in naturally ventilated buildings,the research based on both subjective and objective data was carried out in Chongqing,P. R. China. The characteristics of subjects' clothing regulation function,changes of actual mean thermal comfort vote (AMV) varying with time and acceptable operative temperature in natural conditions were analyzed. In addition,the indicator actual mean vote-actual percentage dissatisfied (AMV-APD) was used to study the actual dissatisfaction with thermal environment. The results indicate that regulative ability by changing clothing under natural ventilated conditions is very significant but limited simultaneously,about 1.7 ℃ per 0.1 clo. Under naturally ventilated conditions,people may have an acceptable operative temperature of 16-28 ℃. Based on the AMV-APD,the actual minimum percentage dissatisfied can reach 4% at AMV of -0.36.
出处 《Journal of Central South University》 SCIE EI CAS 2009年第S1期33-37,共5页 中南大学学报(英文版)
基金 Projects(50838009, 50678179) supported by the National Natural Science Foundation of China Projects(2006BAJ02A09, 2006BAJ02A13-4) supported by the National Key Technologies R & D Program of China Project(200909A1001) supported by Chongqing University Postgraduates’ Innovative Team Building Project
关键词 THERMAL COMFORT THERMAL environment actual mean VOTE (AMV) actual PERCENTAGE dissatisfied (APD) natural ventilation OPERATIVE temperature thermal comfort thermal environment actual mean vote (AMV) actual percentage dissatisfied (APD) natural ventilation operative temperature
  • 相关文献

参考文献4

二级参考文献24

  • 1徐小林,李百战,罗明智.室内热湿环境对人体舒适性的影响分析[J].制冷与空调(四川),2004,18(4):55-58. 被引量:31
  • 2罗明智,李百战,徐小林.重庆夏季教室热环境研究[J].重庆建筑大学学报,2005,27(1):88-91. 被引量:28
  • 3郭利华 朱能 蒋薇.人体热舒适的试验研究[A]..全国暖通空调制冷2002年学术论文集[C].北京:中国建筑工业出版社,2002..
  • 4Brager G S, de Dear R. Thermal adaptation in thebuilt environment: a literature review [J]. Energy and Buildings, 1998, 27:83-96
  • 5Humphreys M. Outdoor temperature and comfort indoors[J]. Building Research and Practice, 1978(3/4)
  • 6Auliciems A, de Dear R. Air conditioning in Australia I.. human thermal factors[J]. Architectural Science Review, 1986,29 : 67- 75
  • 7Nicol F J, Raia I A, Allaudin A, et al. Climatic variations in comfortable temperatures: the Pakistan pmjects[J]. Energy and Buildings, 1999,30:261-279
  • 8Kwok Wai Horace Mui, Wai Tin Daniel Chan. Adaptive comfort temperature model of airconditioned building in Hong Kong [J]. Building and Environment, 2003,38: 837-852.
  • 9ASHRAE 55-1992. Thermal environmental condi-tions for human occupancy[S].
  • 10ISO 7730. Moderate thermal environments-determina-tion of the PMV and PPD indices and specification of the conditions for thermal comfort[S].

共引文献152

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部