期刊文献+

多层钢框架结构强度折减系数研究 被引量:2

Analysis of Strength Reduction Factor for Multi-Story Steel Frame Structures
在线阅读 下载PDF
导出
摘要 结构强度折减系数是基于强度抗震设计法中确定设计地震作用的关键。我国现行《建筑抗震设计规范》[1](GB 50011—2010,简称《规范》)对不同的结构体系采用单一的强度折减系数,不尽合理。在已有强度折减系数方法基础上,提出了以中震位移限值为极限位移的改进间接确定强度折减系数方法,将其应用于钢框架结构强度折减系数中,并与直接强度折减系数方法进行对比分析,验证了此方法的有效性和准确性,研究表明钢框架结构强度折减系数不受建筑层数的影响,其强度折减系数接近于4。 Structural strength reduction factor is the key to determine earthquake action in strength-based seismic design.The Code for Seismic Design of Buildings(GB 50011—2010)specifies a uniform strength reduction factor for various structure systems,and this may not be reasonable in many situations.This paper presents an improved strength reduction approach utilizing displacement as criteria in moderate earthquakes.The accuracy of the proposed approach is verified through comparing with results from the direct strength reduction approach.The design examples show that strength reduction factor of the steel frame is not related to the number of stories,and the strength reduction coefficient for multi-story steel frames is close to 4.
作者 张伟莉 李钢
出处 《建筑钢结构进展》 北大核心 2013年第5期21-28,64,共9页 Progress in Steel Building Structures
关键词 多层钢框架 强度折减系数 中震位移限值 增量动力时程分析 multi-story steel frame strength reduction factor displacement limit in moderate earthquake Incremental Dynamics Analysis(IDA)