期刊文献+

The research progress of brain natriuretic peptide in evaluation of weaning from mechanical ventilation

在线阅读 下载PDF
导出
摘要 Mechanical ventilation provide important support organ function in critical ill patients. However, mechanical ventilation can produce many complications. Patients should be weaned from mechanical ventilation promptly. It is difficult to identify which patients are suitable for weaning, and studies show that 4%-23% of patients who have passed SBT can not be successfully weaning. There is many reasons for weaning failure. Cardiac function may play a key role. Brain natriuretic peptide(BNP) is a powerful biomarker for the diagnosis of heart failure. BNP has been shown to help determine whether weaning failure is caused by cardiovascular dysfunction.
出处 《Journal of Hainan Medical University》 2017年第6期163-166,共4页 海南医学院学报(英文版)
基金 the National Natural Science Foundation of China(81570069).
作者简介 Corresponding author:Qiong Liu,Department of Emergency,the First Affiliated Hospital of Chongqing Medical University,Chongqing,400016,PR China.Tel:18680997675,E-mail:liuqiong0219@163.com
  • 相关文献

参考文献1

二级参考文献16

  • 1罗祖金,詹庆元,孙兵,王辰.自主呼吸试验的操作与临床应用[J].中国呼吸与危重监护杂志,2006,5(1):60-62. 被引量:59
  • 2王玉堂.ESC急性心力衰竭诊断及治疗指南解读[J].心血管病学进展,2006,27(2):139-144. 被引量:18
  • 3陆再英,钟南山.内科学[M].7版.北京:人民卫生出版社,2008:775.
  • 4Mekontso-Dessap A, de Prost N. B-type natriuretic peptide and weaning from mechanical ventilation [ J ]. Intensive Care Med, 2006, 32(10) : 1529-1536.
  • 5Esteban A, Alia I, Gordo F, et al. Extubation outcome after spontaneous breathing trials with T-tube or pressure support ventilation. The Spanish Lung Failure Collaborative Group [ J ].Am J Respir Crit Care Med, 1997, 156(2 Pt 1 ) : 459-465.
  • 6Epstein SK, Ciubotaru RL, Wong JB. Effect of failed extuhation on the outcome of mechanical ventilation [ J ]. Chest, 1997, 112 ( 1 ) : 186-192.
  • 7Vassil.akopoulos T, Zakynthinos muscles and weaning failure [ J ]. 2383-2400.
  • 8Vassilakopoulos T, Zakynthinos S, Roussos C. The tension-time index and the frequency/tidal volume ratio are the major pathophysiologic determinants of weaning failure and success [ J ]. Am J Respir Crit Care Med, 1998, 158(2) :378-385.
  • 9Jubran A, Mathru M, Dries D, et al. Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof [ J ]. Am J Respir Crit Care Med, 1998, 158(6) :1763-1769.
  • 10Lemaire F, Teboul JL, Cinotti L, et al. Acute left ventricular dysfunction during unsuccessful weaning from mechanical ventilation [ J ]. Anesthesiology, 1988, 69 ( 2 ) : 171-179.

共引文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部