关于中心静脉导管封管液残存率的体外研究 被引量:3

An in vitro study about the remaining rate of sealing fluid in central venous catheters
在线阅读 下载PDF
导出
摘要 目的 观察中心静脉导管0~96h封管液时间分段梯度浓度,总结封管液的浓度-时间的变化规律. 方法 导管垂直置于l000ml二级反渗水的烧瓶内,向导管静脉端注入等标量容积的封管液.从导管尖端到尾部依次分为6段留取标本,此过程重复10次.计算出平均浓度,描绘出浓度-时间曲线图,进行4参数模型曲线拟合求出参数. 结果 封管后即刻,导管尖段残存浓度为(15.8±0.8)mmol/L,5min时快速下降到(9.9±0.9)mmol/L,然后缓慢下降到96h的(0.7±0.1)mmol/L;第2段的残存浓度从即刻的(22.4±0.6)mmol/L逐渐下降到96h的(2.7±0.4)mmol/L;第1至第6段下降速度依次变慢,96h时第4、5和6段残存浓度相似.拟合方程Y=(A-D)/[1+(T/C)B] +D能啮合药时曲线图(R2>90). 结论 封管后即刻管尖端封管液即己流失,在5min内快速流失,封管液浓度明显下降.可根据拟合方程推算出临床上合适的封管液浓度和有效作用时间从而制定合理的封管策略. Objective To observe the gradient concentration of sealing fluid sealed in central vein catheters for 0-96 hours,and to summarize the concentration-time changing rule of the sealing fluid.Methods A catheters was placed vertically in a flask containing 1,000 ml reverse-osmosis water of secondary grade.The scaled volume of sealing fluid was injected into the venous end of the catheter.Samples were collected from tip to tail of the catheter in six parts,and the procedure was repeated 10 times.The average concentration was calculated,the concentration-time curve was drawn,and the parameters were obtained by fitting the four-parameter model curve.Results Immediately after tube closure,the concentration remained in the tip segment was 15.8±0.8 mmol/L,rapidly decreased to 9.9±0.9 mmol/L in 5 minutes,then slowly decreased to 0.7±0.1 mmol/L after 96 hours.The concentration remained in the second segment gradually decreased from 22.4±0.6 mmol/L immediately after tube closure to 2.7±0.4 mmol/L after 96 hours.The decline rate slowed down along the first to sixth segments.The concentration of remained sealing fluid was similar in the fourth,fifth and sixth segments after 96 hours.Fitting equation Y=(A-D)/[1+(T/C)~B]+D can mesh with the propellant curve(R^2>90).Conclusion Immediately after sealing,the sealing fluid at the tip of the tube lost and quickly and further lost within 5 minutes,associated with significant decrease of sealing fluid concentration.According to the fitting equation,the suitable concentration and effective time of sealing fluid can be calculated and a reasonable sealing strategy can be worked out.
作者 张国胜 焦夏 吝泽华 左力 ZHANG Guo-sheng;JIAO Xia;LIN Ze-hua;ZUO Li(lDepartment of Nephrology,PekingUniversityPeoplejsHospital,Beij'ing 100044,China;Department of Nephrology,Zhengzhou Traditional Chinese Medicine Hospiml Affiliated to Henan University of Traditional Chinese Medicine,Zhengzhou 15000Z China;Department ofNe—phrology,Yuncheng Tongde Hospital,Yuncheng 044000,China;Department ofNephrology,Beijing Boai Hos—pital,Beijing 100068,China)
出处 《中国血液净化》 CSCD 2019年第8期564-567,共4页 Chinese Journal of Blood Purification
关键词 中心静脉导管 封管液 残存率 Central venous catheter Sealing fluid Remaining rate
作者简介 通讯作者:左力,Email:zuoli@bjmu.edu.cn
  • 相关文献

参考文献1

二级参考文献18

  • 1Clinical practice guidelines for hemodialysis adequacy, update 2006[J]. Am .J Kidney Dis, 2006,48 Suppl(1):2 90.
  • 2VanhoJder V, Hoenich N, RingoJr S. Morbidity and mortal ity of central venous catheter hemodia]ysis: a review of 10 years' experience[J]. Nephron, 1987,47(4):274- 279.
  • 3Pastan S, Soueie JM, cClellan WM. Vascular access and increased risk of death among hemodialysis patients [J]. Kidney Int, 2002,62(2):620 626.
  • 4Mendelssohn I)C, Ethier J, Eider SJ, et al. tlaemudialy- sis vascular access problems in Canada: results from the Dialysis Outcomes and Practice Patterns Study (DOPPS II) [J]. Nephrol Dial Transplant, 2006,2I(3):721 728.
  • 5US Renal Data System. USRDS 2014 Annual Data Report: At- las of chronic kidney disease and end-stage renal dis ease in the United States [DB/OL], United States: US Renal Data System. 201412015-i2 Old. http://www, usrds. org/2OJ4/view/Default, aspx.
  • 6Vorweg M, Monaca E, Doehn M, et al. The 'heparin lock': cause for iatrogenie coagulopathy[J]. Eur J Anaeslhesi ol, 2006, 23(1):50 53.
  • 7Karaaslan H, Peyronnet P, Benevent D, eL al. Risk of heparin lock-related bleeding when using indwelling ve nous catheter in haemodialysis[J]. Nephrol Dial Troms plant, 2001,16(10):2072 2074.
  • 8Pepper RJ, Gale DP, Wajed J, et al. Inadvertent postdi- alysis anticoagulation due to heparin line locks[J]. Hemodial Int, 2007,11(4):430 434.
  • 9Weijmer MC, van den Dorpel MA, Van de-gen PJ, et al. Randomized, clinical trial comparison of trisodium ci trate 30% and heparin as catheter-locking solution in hemodialysis patients[J]. J Am Soc Nephrol, 2005,16(9): 2769-2777.
  • 10Markota I, Markota D, Tomic M. Measuring of the heparin leakage into the circulation from central venous cathe- ters-- an in vivo study[J]. Nephrol Dial Transplant, 2009,24(5):1550 1553.

共引文献12

同被引文献57

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部