期刊文献+

平疫结合综合医院电气设计要点 被引量:3

Key Points in the Electrical Design of a General Hospital Combining Functions in Normal Times and During an Epidemic
在线阅读 下载PDF
导出
摘要 以某新建平疫结合综合医院为例,分析平疫结合综合医院平时、疫情时用电情况,根据负荷性质及负荷容量合理确定供配电技术方案;从高低压配电、照明、风机控制、灯具选型、线路防护等方面阐述平疫结合综合医院电气设计要点及相关技术措施。 A new general hospital combining functions in normal times and during an epidemic is taken as an example to analyze the electricity utilization in the hospital in normal times and during an epidemic and reasonably determine the technical schemes for power supply and distribution based on load nature and capacity.The key points in the electrical design of a general hospital combining functions in normal times and during an epidemic and relevant technical measures are set out in terms of highand low-voltage distribution,lighting,fan control,luminaire selection and line protection,etc.
作者 刘敏 李蔚 张宽 LIU Min;LI Wei;ZHANG Kuan(CITIC General Institute of Architectural Design and Research Co.,Ltd.,Wuhan 430030,China)
出处 《建筑电气》 2022年第11期13-18,共6页 Building Electricity
关键词 平疫结合 平疫转换 负荷分级 柴油发电机 UPS 负压风机控制 灯具选型 线路防护 combining functions in normal times and during an epidemic transformation from normal mode to epidemic mode load classification diesel generator UPS negative pressure fan control luminaire selection line protection
作者简介 刘敏,女,中信建筑设计研究总院有限公司,正高职高级工程师,机电三院电气副总工程师;李蔚,男,中信建筑设计研究总院有限公司,正高职高级工程师,总院副总工程师,电气总工程师;张宽,男,中信建筑设计研究总院有限公司,正高职高级工程师,机电三院电气总工程师。
  • 相关文献

参考文献2

二级参考文献6

  • 1中华人民共和国建设部.民用建筑电气设计规范(JGJ16-2008)[S].北京:中国建筑工业出版社,2008.
  • 2陆伟良,沈崇德,许作民,等.实用医院智能化系统工程[M].南京:东南大学出版社,2009:20-28.
  • 3中华人民共和国住房和城乡建设部.医疗建筑电气设计规范(JGJ312-2013)[S].北京:中国建筑工业出版社,2014.
  • 4中华人民共和国住房和城乡建设部.医院洁净手术部建筑技术规范(GB50333-2013)[S].北京:中国建筑工业出版社,2014.
  • 5张一鸣,张园.谈负压隔离病房楼空调通风系统自动控制设计[J].建筑设计管理,2008,25(3):57-60. 被引量:8
  • 6陆仕斌.潍坊医学院门诊病房综合楼智能化信息系统设计[J].现代建筑电气,2013,4(S1):363-367. 被引量:2

共引文献5

同被引文献10

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部