期刊文献+

地铁车站渗漏防治 被引量:4

Prevention and Control of Leakage in Subway Stations
在线阅读 下载PDF
导出
摘要 随着全球经济的下行,以及国内新基建的建设热潮,国家开始加大对基础设施的投入,城市轨道交通得到快速发展,地铁项目投资与建设也越来越多。当前城市地铁地下车站的建设中,渗漏问题是普遍性的难题,还无法采取有效的方式进行根治。为降低本工程渗漏率,提升车站防水质量,以保证地铁良好有效运营,以车站防水设计为依据,以深圳地铁13号线某站为依托,全面分析地下车站渗漏水的主要原因,提出防治措施及出现渗漏问题的治理方法。 With the decline of global economy and the construction upsurge of new infrastructure in China,the country begins to increase the investment in infrastructure,urban rail transit has developed rapidly,and the investment and construction of metro projects are increasing.At present,the leakage problem is a universal problem in the construction of urban subway stations,and it can not be cured by effective methods.In order to reduce the leakage rate of the project,improve the waterproof quality of the station,and ensure the good and effective operation of the subway,based on the waterproof design of the station and a station of Shenzhen Metro Line 13,this paper comprehensively analyzes the main causes of the leakage water of the underground station,and puts forward the prevention measures and the treatment methods for the leakage problems for reference.
作者 陈磊 詹兴家 朱桂成 覃挺 CHEN Lei;ZHAN Xingjia;ZHU Guicheng;QIN Ting(China Construction Eighth Engineering Division South China Branch Co.,Ltd.,Guangzhou,Guangdong 510665,China)
出处 《施工技术》 CAS 2020年第S01期808-810,共3页 Construction Technology
关键词 地铁车站 主体结构 渗漏防治 堵漏 subway station main structure leakage prevention leakage stoppage
作者简介 陈磊,助理工程师;E-mail:719954691@qq.com
  • 相关文献

参考文献2

二级参考文献6

共引文献7

同被引文献40

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部