校圆加热不当引起的除氧器筒体失效

Failure of Deaerator Cylinder Caused by Improper Heating during Calibrating Circle
在线阅读 下载PDF
导出
摘要 采用宏观检查、化学成分分析、微观组织观察及力学性能检测等方法,对某发电厂除氧器筒体母材开裂泄漏进行失效分析。结果表明:该母材开裂原因是现场安装制造过程中采用火焰校圆时,加热温度过高或时间过长造成筒体母材组织发生变化,性能下降,从而导致脆性开裂。 By means of macroscopical inspection,chemical composition analysis,microstructure observation and mechanical property test,the failure analysis of base metal cracking and leakage of deaerator tube in a power plant was carried out.The results show that,the cracking of the base metal is caused by the excessive heating temperature or too long time during flame correction in the process of installation and manufacture,which results in the change of the structure of the parent metal and the deterioration of the properties of the base metal and leads to brittleness cracking.
作者 姚祥宏 陈忠兵 吕一仕 孙志强 王淦刚 YAO Xianghong;CHEN Zhongbing;LYU Yishi;SUN Zhiqiang;WANG Gan'gang(Suzhou Nuclear Power Research Institute Co.,Ltd.,Suzhou 215004,China)
出处 《热加工工艺》 北大核心 2020年第4期157-159,共3页 Hot Working Technology
关键词 除氧器 失效分析 微观组织 力学性能 deaerator failure analysis microstructure mechanical property
作者简介 姚祥宏(1991-),男,江苏苏州人,助理工程师,硕士,主要从事电站金属失效分析、焊接工艺开发,电话:15895573394,E-mail:519912846@qq.com