摘要
本文以上海某设备厂房为例,详细介绍了厂房暖通空调系统设计方案,主要包括空调系统、通风系统和防排烟系统的设计。针对厂房车间的类型及规模,采用多联机系统和全空气系统;阐述了上海地标防排烟新规范与国标规范的显著差异,以及适用于本项目的防排烟系统的设计方法;针对厂房车间特殊功能,合理采用风口型式。
Taking an equipment plant in Shanghai as an example,this paper introduces in detail the design scheme of the HVAC system of the plant,mainly including the design of HVAC system,ventilation system,anti-smoke and smoke extraction system.According to the type and scale of the plant workshop,multi-online system and full-air system are adopted;The significant differences between the new Shanghai landmark smoke prevention specification and the national standard specification were expounded,and the design method of the anti-smoke and smoke extraction system applicable to this project was expounded.For the special functions of the plant,the air outlet type is reasonably adopted.
作者
邵杰
SHAO Jie(Shanghai Construction Design&Research Institute Co.,LTD,Xuhui District,shanghai,China)
出处
《制冷》
2023年第4期13-17,共5页
Refrigeration
关键词
空调系统
防排烟系统
上海地标防排烟新规范
风口型式
HVAC System
Anti-smoke Extraction System
Shanghai Landmark Smoke Prevention New Specification
Air Outlet Type
作者简介
邵杰(1992-),女,工程师,硕士研究生,主要研究方向,暖通设计。E-mail:usstshaojie@163.com