This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a disti...This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a distinctive boundary structure.This approach capitalizes on the boundary’s capacity to attenuate the high-frequency component of fault signals,resulting in a variation in the high-frequency transient energy ratio when faults occur inside or outside the line.During internal line faults,the high-frequency transient energy at the checkpoints located at both ends surpasses that of its neighboring lines.Conversely,for faults external to the line,the energy is lower compared to adjacent lines.EWT is employed to decompose the collected fault current signals,allowing access to the high-frequency transient energy.The longitudinal protection for the traction network line is established based on disparities between both ends of the traction network line and the high-frequency transient energy on either side of the boundary.Moreover,simulation verification through experimental results demonstrates the effectiveness of the proposed protection scheme across various initial fault angles,distances to faults,and fault transition resistances.展开更多
CF3I gas mixtures have attracted considerable attention as potential environmentally-friendly alternatives to SF6 gas,owing to their excellent insulating performance.This paper attempts to study the CF3I ternary gas m...CF3I gas mixtures have attracted considerable attention as potential environmentally-friendly alternatives to SF6 gas,owing to their excellent insulating performance.This paper attempts to study the CF3I ternary gas mixtures with c-C4F8 and buffer gases N2 and CO2 by considering dielectric strength from electron transport parameters based on the Boltzmann method and synergistic effect analysis,compared with SF6 gas mixtures.The results confirm that the critical electric field strength of CF3I/c-C4F8/70%CO2 is greater than that of 30%SF6/70%CO2 when the CF3I content is greater than 17%.Moreover,a higher content of c-C4F8 decreases the sensitivity of gas mixtures to an electric field,and this phenomenon is more obvious in CF3I/c-C4F8/CO2 gas mixtures.The synergistic effects for CF3I/c-C4F8/70%N2 were most obvious when the c-C4F8 content was approximately 20%,and for CF3I/c-C4F8/70%CO2 when the c-C4F8 content was approximately 10%.On the basis of this research,CF3I/c-C4F8/70%N2 shows better insulation performance when the c-C4F8 content is in the15%–20%range.For CF3I/c-C4F8/70%CO2,when the c-C4F8 content is in the 10%–15%range,the gas mixtures have excellent performance.Hence,these gas systems might be used as alternative gas mixtures to SF6 in high-voltage equipment.展开更多
For the load modeling of a large power grid,the large number of substations covered by it must be segregated into several categories and,thereafter,a load model built for each type.To address the problem of skewed clu...For the load modeling of a large power grid,the large number of substations covered by it must be segregated into several categories and,thereafter,a load model built for each type.To address the problem of skewed clustering tree in the classical hierarchical clustering method used for categorizing substations,a fair hierarchical clustering method is proposed in this paper.First,the fairness index is defined based on the Gini coefficient.Thereafter,a hierarchical clustering method is proposed based on the fairness index.Finally,the clustering results are evaluated using the contour coefficient and the t-SNE two-dimensional plane map.The substations clustering example of a real large power grid considered in this paper illustrates that the proposed fair hierarchical clustering method can effectively address the problem of the skewed clustering tree with high accuracy.展开更多
泥石流是我国西南山区常见的地质灾害。架空输电杆塔在泥石流的冲击下往往发生基础破坏甚至会造成杆塔倒塌。首先采用光滑粒子流体动力学(smoothed particle hydrodynamics,简称SPH)方法和有限元方法(finite element method,简称FEM)相...泥石流是我国西南山区常见的地质灾害。架空输电杆塔在泥石流的冲击下往往发生基础破坏甚至会造成杆塔倒塌。首先采用光滑粒子流体动力学(smoothed particle hydrodynamics,简称SPH)方法和有限元方法(finite element method,简称FEM)相耦合的三维数值方法模拟了泥石流对杆塔基础的冲击作用;在与相关模型试验结果验证的基础上,开展了不同泥石流密度、黏度系数及初始速度条件下对输电塔基础的冲击力作用的参数分析;研究结果表明:随着泥石流初始速度的增加,冲击力峰值会随之增大;前排基础的冲击力峰值均大于后排基础;泥石流冲击过程特性受到泥石流密度和黏度系数影响。与稀性泥石流相比:黏性泥石流冲击基础后,基础下游真空区相对要小;此外,将数值模拟结果与Kwan冲击力公式及铁二院推荐的冲击压力设计公式预测值进行对比分析可以发现:Kwan冲击力公式能较好地预测出基础所受泥石流冲击力的平均趋势,最大预测误差低于30%,铁二院公式预测的稀性和黏性泥石流的冲击压力平均偏低分别约17%和28%。相关研究结果有望为泥石流频发区域输电塔基础的设计和风险评估提供一定的参考依据。展开更多
基金supported by the National Natural Science Foundation of China(51767012)Curriculum Ideological and Political Connotation Construction Project of Kunming University of Science and Technology(2021KS009)Kunming University of Science and Technology Online Open Course(MOOC)Construction Project(202107).
文摘This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a distinctive boundary structure.This approach capitalizes on the boundary’s capacity to attenuate the high-frequency component of fault signals,resulting in a variation in the high-frequency transient energy ratio when faults occur inside or outside the line.During internal line faults,the high-frequency transient energy at the checkpoints located at both ends surpasses that of its neighboring lines.Conversely,for faults external to the line,the energy is lower compared to adjacent lines.EWT is employed to decompose the collected fault current signals,allowing access to the high-frequency transient energy.The longitudinal protection for the traction network line is established based on disparities between both ends of the traction network line and the high-frequency transient energy on either side of the boundary.Moreover,simulation verification through experimental results demonstrates the effectiveness of the proposed protection scheme across various initial fault angles,distances to faults,and fault transition resistances.
基金supported by National Natural Science Foundation of China(No.51337006)。
文摘CF3I gas mixtures have attracted considerable attention as potential environmentally-friendly alternatives to SF6 gas,owing to their excellent insulating performance.This paper attempts to study the CF3I ternary gas mixtures with c-C4F8 and buffer gases N2 and CO2 by considering dielectric strength from electron transport parameters based on the Boltzmann method and synergistic effect analysis,compared with SF6 gas mixtures.The results confirm that the critical electric field strength of CF3I/c-C4F8/70%CO2 is greater than that of 30%SF6/70%CO2 when the CF3I content is greater than 17%.Moreover,a higher content of c-C4F8 decreases the sensitivity of gas mixtures to an electric field,and this phenomenon is more obvious in CF3I/c-C4F8/CO2 gas mixtures.The synergistic effects for CF3I/c-C4F8/70%N2 were most obvious when the c-C4F8 content was approximately 20%,and for CF3I/c-C4F8/70%CO2 when the c-C4F8 content was approximately 10%.On the basis of this research,CF3I/c-C4F8/70%N2 shows better insulation performance when the c-C4F8 content is in the15%–20%range.For CF3I/c-C4F8/70%CO2,when the c-C4F8 content is in the 10%–15%range,the gas mixtures have excellent performance.Hence,these gas systems might be used as alternative gas mixtures to SF6 in high-voltage equipment.
基金supported by the Major Science and Technology Project of Yunnan Province entitled“Research and Application of Key Technologies of Power Grid Operation Analysis and Protection Control for Improving Green Power Consumption”(202002AF080001)the China South Power Grid Science and Technology Project entitled“Research on Load Model and Modeling Method of Yunnan Power Grid”(YNKJXM20180017).
文摘For the load modeling of a large power grid,the large number of substations covered by it must be segregated into several categories and,thereafter,a load model built for each type.To address the problem of skewed clustering tree in the classical hierarchical clustering method used for categorizing substations,a fair hierarchical clustering method is proposed in this paper.First,the fairness index is defined based on the Gini coefficient.Thereafter,a hierarchical clustering method is proposed based on the fairness index.Finally,the clustering results are evaluated using the contour coefficient and the t-SNE two-dimensional plane map.The substations clustering example of a real large power grid considered in this paper illustrates that the proposed fair hierarchical clustering method can effectively address the problem of the skewed clustering tree with high accuracy.
文摘泥石流是我国西南山区常见的地质灾害。架空输电杆塔在泥石流的冲击下往往发生基础破坏甚至会造成杆塔倒塌。首先采用光滑粒子流体动力学(smoothed particle hydrodynamics,简称SPH)方法和有限元方法(finite element method,简称FEM)相耦合的三维数值方法模拟了泥石流对杆塔基础的冲击作用;在与相关模型试验结果验证的基础上,开展了不同泥石流密度、黏度系数及初始速度条件下对输电塔基础的冲击力作用的参数分析;研究结果表明:随着泥石流初始速度的增加,冲击力峰值会随之增大;前排基础的冲击力峰值均大于后排基础;泥石流冲击过程特性受到泥石流密度和黏度系数影响。与稀性泥石流相比:黏性泥石流冲击基础后,基础下游真空区相对要小;此外,将数值模拟结果与Kwan冲击力公式及铁二院推荐的冲击压力设计公式预测值进行对比分析可以发现:Kwan冲击力公式能较好地预测出基础所受泥石流冲击力的平均趋势,最大预测误差低于30%,铁二院公式预测的稀性和黏性泥石流的冲击压力平均偏低分别约17%和28%。相关研究结果有望为泥石流频发区域输电塔基础的设计和风险评估提供一定的参考依据。