A novel thickness measurement method for surface insulation coating of silicon steel based on NIR spectrometry is explored.The NIR spectra of insulation coating of silicon steel were collected by acousto-optic tunable...A novel thickness measurement method for surface insulation coating of silicon steel based on NIR spectrometry is explored.The NIR spectra of insulation coating of silicon steel were collected by acousto-optic tunable filter(AOTF) NIR spectrometer.To make full use of the effective information of NIR spectral data,discrete binary particle swarm optimization(DBPSO) algorithm was used to select the optimal wavelength variates.The new spectral data,composed of absorbance at selected wavelengths,were used to create the thickness quantitative analysis model by kernel partial least squares(KPLS) algorithm coupled with Boosting.The results of contrast experiments showed that the Boosting-KPLS model could efficiently improve the analysis accuracy and speed.It indicates that Boosting-KPLS is a more accurate and robust analysis method than KPLS for NIR spectral analysis.The maximal and minimal absolute error of 30 testing samples is respectively-0.02 μm and 0.19 μm,and the maximal relative error is 14.23%.These analysis results completely meet the practical measurement need.展开更多
In order to solve the problems of TEV(transient earth voltage) utilization,such as single judgment criterion and low reliability of PD detection in HV switchboard,this paper discussed the method on how to make a bette...In order to solve the problems of TEV(transient earth voltage) utilization,such as single judgment criterion and low reliability of PD detection in HV switchboard,this paper discussed the method on how to make a better utilization of TEV in PD detection of metal-enclosed switchgears.Through discussing the relationship among the temporal phase,number of pulses and threshold of measuring and extracting the features corresponding to different typical defects,test results showed that the needle discharge distributed in 0°~90°and 200°~340°with low appearance probability above high measurement threshold;internal discharge distributed in 0°~90°and 270°~315°,and showed a similar decreasing trend under increasing of the threshold in the two regions;suspended discharge distributed in 0°~135°and 180°~315°where the PD in negative half periods decreased more seriously than those in positive half with increasing threshold.These results followed the doctrine of consistency with the conclusions that were obtained by using the traditional pulse current method.The possibility of using TEV method to make identification of PD defects has been proved to prepare for further research.展开更多
基金National High Technology Research and Development Program of China(2009AA04Z131)Natural Science Foundation of China (50877056)
文摘A novel thickness measurement method for surface insulation coating of silicon steel based on NIR spectrometry is explored.The NIR spectra of insulation coating of silicon steel were collected by acousto-optic tunable filter(AOTF) NIR spectrometer.To make full use of the effective information of NIR spectral data,discrete binary particle swarm optimization(DBPSO) algorithm was used to select the optimal wavelength variates.The new spectral data,composed of absorbance at selected wavelengths,were used to create the thickness quantitative analysis model by kernel partial least squares(KPLS) algorithm coupled with Boosting.The results of contrast experiments showed that the Boosting-KPLS model could efficiently improve the analysis accuracy and speed.It indicates that Boosting-KPLS is a more accurate and robust analysis method than KPLS for NIR spectral analysis.The maximal and minimal absolute error of 30 testing samples is respectively-0.02 μm and 0.19 μm,and the maximal relative error is 14.23%.These analysis results completely meet the practical measurement need.
基金Supported by National Natural Science Foundation of China(50907051)
文摘In order to solve the problems of TEV(transient earth voltage) utilization,such as single judgment criterion and low reliability of PD detection in HV switchboard,this paper discussed the method on how to make a better utilization of TEV in PD detection of metal-enclosed switchgears.Through discussing the relationship among the temporal phase,number of pulses and threshold of measuring and extracting the features corresponding to different typical defects,test results showed that the needle discharge distributed in 0°~90°and 200°~340°with low appearance probability above high measurement threshold;internal discharge distributed in 0°~90°and 270°~315°,and showed a similar decreasing trend under increasing of the threshold in the two regions;suspended discharge distributed in 0°~135°and 180°~315°where the PD in negative half periods decreased more seriously than those in positive half with increasing threshold.These results followed the doctrine of consistency with the conclusions that were obtained by using the traditional pulse current method.The possibility of using TEV method to make identification of PD defects has been proved to prepare for further research.