The low field nuclear magnetic resonance (NMR), as a nondestructive and noninvasive technique, was employed to investigate the water distribution and content in cement paste with different water-to-cement ratio (w/c r...The low field nuclear magnetic resonance (NMR), as a nondestructive and noninvasive technique, was employed to investigate the water distribution and content in cement paste with different water-to-cement ratio (w/c ratio) during early and later hydration stages. From the water distribution spectrum deduced from relaxation time distribution in paste, it is suggested that the water fills in the capillary pores at initial period, and then diffuses to the mesopores and gel pores in hydration products with the hydration proceeding. The decrease of peak area in water distribution spectrum reflects the transformation from physically bound water to chemically bound water. In addition, based on the connection between relaxation time and pore size, the relative content changes of water in various states and constrained in different types of pores were also measured. The results demonstrate that it is influenced by the formation of pore system and the original water-to-cement ratio in the paste. Consequently, the relative content of capillary water is dropped to less than 2% in the paste with low w/c ratio of 0.3 when being hydrated for 1 d, while the contents are still 16% and 36% in the pastes with w/c ratios of 0.4 and 0.5, respectively.展开更多
An element coupling model (ECM) method was proposed to simulate the global behavior and local damage of a structure.In order to reflect the local damage and improve the computational efficiency,three-dimensional (3D) ...An element coupling model (ECM) method was proposed to simulate the global behavior and local damage of a structure.In order to reflect the local damage and improve the computational efficiency,three-dimensional (3D) solid elements and one-dimensional (1D) beam element were coupled by the multi-point constraint equations.A reduced scale 1?8 model test was simulated by the ECM and a full three dimensional model (3DM) contrastively.The results show that the global behavior and local damages of ECM agree well with the test and 3DM.It is indicated that the proposed method can be used in the structural nonlinear analysis accurately and efficiently.展开更多
The equations governing wind-induced internal pressure responses for a two-compartment building with a dominant opening and background porosity were derived.The unsteady form of the Bernoulli equation,the law of mass ...The equations governing wind-induced internal pressure responses for a two-compartment building with a dominant opening and background porosity were derived.The unsteady form of the Bernoulli equation,the law of mass conservation,and adiabatic equation were used for the derivation.The precision of the governing equations was verified by a wind tunnel test on a rigid model of a low-rise building.The results show that the governing equations can effectively analyze the wind-induced internal pressure responses.The internal pressure responses in both compartments are suppressed due to the additional damping provided by background porosity.The responses of internal pressure in both compartments,especially in the compartment without an external opening,decrease with increased lumped leakage area.展开更多
Spectrum characteristics of different types of seismic waves and dynamic response characteristics of super high-rise building structures under long-period ground motions were comparatively analyzed. First, the ground ...Spectrum characteristics of different types of seismic waves and dynamic response characteristics of super high-rise building structures under long-period ground motions were comparatively analyzed. First, the ground response wave (named LS-R wave) of a soft soil site with deep deposit, taking long-period bedrock seismic record as input, was calculated by wave propagation method. After that, a TOMAKOMAI station long-period seismic record from the Tokachi-Oki earthquake and conventional E1-Centro wave were also chosen. Spectrum characteristics of these waves were analyzed and compared. Then, a series of shaking table tests were performed on a 1:50 scale super high-rise structural model under these seismic waves. Furthermore, numerical simulation of the prototype structure under these excitations was conducted, and structure damages under different intensive ground motions were discussed. The results show that: 1) Spectrum characteristics of ground response wave are significantly influenced by soft soil site with deep deposit, and the predominant period has an increasing trend. 2) The maximum acceleration amplification factor of the structure under the TOM wave is two times that under the E1-Centro wave; while the maximum displacement response of the structure under the TOM wave is 4.4 times that under the E1-Centro wave. Long-period ground motions show greater influences on displacement responses than acceleration responses for super high-rise building structures. 3) Most inelastic damage occurs at the upper 1/3 part of the super high-rise building when subjected to long-period ground motions.展开更多
Analyses of the effects of some parameters were performed to determine the admittance functions in a common two-compartment building with background porosity by the imposed excitation method.Variations of the magnific...Analyses of the effects of some parameters were performed to determine the admittance functions in a common two-compartment building with background porosity by the imposed excitation method.Variations of the magnification factors of fluctuating internal pressures were analyzed using 96 model cases under random fluctuating external pressure,and then corresponding design equations were fitted.The results show that the Helmholtz resonance peaks of the admittance functions in both compartments increase with increasing the area of windward or partition wall opening.With increasing the volume of the compartment with an external opening,the resonance peak in this compartment at the higher Helmholtz frequency significantly decreases,at the same time,the resonance peak in the other compartment at the lower Helmholtz frequency also decreases.With increasing the volume of the compartment with background porosity,both resonance peaks in this compartment at the lower and higher Helmholtz frequencies decrease,meanwhile,the resonance peak at the lower Helmholtz frequency for the other compartment also decreases,whereas the resonance peak at the higher Helmholtz frequency increases.Both resonance peaks of the admittance functions in the two compartments decrease with increasing the amplitude of fluctuating external pressure coefficients or reference wind speed.展开更多
Autoclaved aerated concrete(AAC) panels have ultra-light weight,excellent thermal insulation and energy absorption,so it is an ideal building material for protective structures.To improve the blast resistance of the A...Autoclaved aerated concrete(AAC) panels have ultra-light weight,excellent thermal insulation and energy absorption,so it is an ideal building material for protective structures.To improve the blast resistance of the AAC panels,three schemes are applied to strengthen the AAC panels through spraying 4 mm thick polyurea coating from top,bottom and double-sides.In three-point bending tests,the polyurea-coated AAC panels have much higher ultimate loads than the un-coated panels,but slightly lower than those strengthened by the carbon fiber reinforced plastics(CEFRPs).Close-in explosion experiments reveal the dynamic strengthening effect of the polyurea coating.Critical scaled distances of the strengthened AAC panels are acquired,which are valuable for the engineering application of the AAC panels in the extreme loading conditions.Polyurea coatings efficiently enhance the blast resistance of the bottom and double-sided polyurea-coated AAC panels.It is interesting that the polyurea-coated AAC panels have much more excellent blast resistance than the CFRP reinforced AAC panels,although the latter have better static mechanical properties.展开更多
The 2-dimensional unsteady aerodynamic forces,in the context of both a thin airfoil where theory of potential flow is always applicable and a bluff bridge-deck section where separated flow is typically induced,are inv...The 2-dimensional unsteady aerodynamic forces,in the context of both a thin airfoil where theory of potential flow is always applicable and a bluff bridge-deck section where separated flow is typically induced,are investigated from a point of view of whether or not they conform to the principle of linear superposition in situations of various structural motions and wind gusts.It is shown that some basic preconditions that lead to the linear superposability of the unsteady aerodynamic forces in cases of thin airfoil sections are no longer valid for a bluff section.Theoretical models of bridge aerodynamics such as the one related to flutter-buffeting analysis and those concerning aerodynamic admittance(AA)functions,however,necessitate implicitly this superposability.The contradiction revealed in this work may throw light on the perplexing problem of AA functions pertaining to the description of buffeting loads of bridge decks.Some existing theoretical AA models derived from flutter derivatives according to interrelations valid only for thin airfoil theories,which have been employed rather extensively in bridge aerodynamics,are demonstrated to be illogical.Finally,with full understanding of the preconditions of the applicability of linear superposability of the unsteady aerodynamic forces,suggestions in regard to experiment-based AA functions are presented.展开更多
Wind data were collected during the 2011 typhoon Meari at heights of 10, 20, 30, and 40 m above the ground using a 40 m high anemometer tower in the coastal area near Shanghai Pudong International Airport. Wind speeds...Wind data were collected during the 2011 typhoon Meari at heights of 10, 20, 30, and 40 m above the ground using a 40 m high anemometer tower in the coastal area near Shanghai Pudong International Airport. Wind speeds and directions, turbulence intensities, gust factors, and peaks were analyzed using the time records of wind speed. The results show that turbulence intensity components in longitudinal, lateral, and vertical directions decrease with mean wind speed, regardless of elevations, and the turbulence intensities are in a linear relationship with mean wind speeds. The ratios of three turbulence intensity components(i.e. Iu, Iv, Iw) at heights of 10, 20 and 40 m were calculated and equal to be 1:0.88:0.50, 1:0.84:0.57, and 1:0.9:0.49, respectively. In addition, the gust factors in three directions exhibit a reduction with increasing mean wind speed. The peak factors at different heights show a similar trend and slightly decrease with mean wind speed; average peak factors for all 10-min data from Typhoon Meari are 2.43, 2.48, and 2.47, respectively.展开更多
基金Project(2009CB623105) supported by the National Basic Research Program of ChinaProject(51108341) supported by the National Natural Science Foundation of ChinaProjects(20110490703, 2012T50437) supported by China Postdoctoral Science Foundation
文摘The low field nuclear magnetic resonance (NMR), as a nondestructive and noninvasive technique, was employed to investigate the water distribution and content in cement paste with different water-to-cement ratio (w/c ratio) during early and later hydration stages. From the water distribution spectrum deduced from relaxation time distribution in paste, it is suggested that the water fills in the capillary pores at initial period, and then diffuses to the mesopores and gel pores in hydration products with the hydration proceeding. The decrease of peak area in water distribution spectrum reflects the transformation from physically bound water to chemically bound water. In addition, based on the connection between relaxation time and pore size, the relative content changes of water in various states and constrained in different types of pores were also measured. The results demonstrate that it is influenced by the formation of pore system and the original water-to-cement ratio in the paste. Consequently, the relative content of capillary water is dropped to less than 2% in the paste with low w/c ratio of 0.3 when being hydrated for 1 d, while the contents are still 16% and 36% in the pastes with w/c ratios of 0.4 and 0.5, respectively.
基金Project(2007CB714202) supported by the National Key Basic Research Program of ChinaProject(SLDRCE10-B-07) supported by theMinistry of Science and Technology of China
文摘An element coupling model (ECM) method was proposed to simulate the global behavior and local damage of a structure.In order to reflect the local damage and improve the computational efficiency,three-dimensional (3D) solid elements and one-dimensional (1D) beam element were coupled by the multi-point constraint equations.A reduced scale 1?8 model test was simulated by the ECM and a full three dimensional model (3DM) contrastively.The results show that the global behavior and local damages of ECM agree well with the test and 3DM.It is indicated that the proposed method can be used in the structural nonlinear analysis accurately and efficiently.
基金Project(90715040) supported by the Major Research Program of the National Natural Science Foundation of ChinaProject(50878159) supported by the General Program of the National Natural Science Foundation of China
文摘The equations governing wind-induced internal pressure responses for a two-compartment building with a dominant opening and background porosity were derived.The unsteady form of the Bernoulli equation,the law of mass conservation,and adiabatic equation were used for the derivation.The precision of the governing equations was verified by a wind tunnel test on a rigid model of a low-rise building.The results show that the governing equations can effectively analyze the wind-induced internal pressure responses.The internal pressure responses in both compartments are suppressed due to the additional damping provided by background porosity.The responses of internal pressure in both compartments,especially in the compartment without an external opening,decrease with increased lumped leakage area.
基金Project(50978198) supported by the National Natural Science Foundation of ChinaProject(SLDRCE08-B-03) supported by the Ministry of Science and Technology of China
文摘Spectrum characteristics of different types of seismic waves and dynamic response characteristics of super high-rise building structures under long-period ground motions were comparatively analyzed. First, the ground response wave (named LS-R wave) of a soft soil site with deep deposit, taking long-period bedrock seismic record as input, was calculated by wave propagation method. After that, a TOMAKOMAI station long-period seismic record from the Tokachi-Oki earthquake and conventional E1-Centro wave were also chosen. Spectrum characteristics of these waves were analyzed and compared. Then, a series of shaking table tests were performed on a 1:50 scale super high-rise structural model under these seismic waves. Furthermore, numerical simulation of the prototype structure under these excitations was conducted, and structure damages under different intensive ground motions were discussed. The results show that: 1) Spectrum characteristics of ground response wave are significantly influenced by soft soil site with deep deposit, and the predominant period has an increasing trend. 2) The maximum acceleration amplification factor of the structure under the TOM wave is two times that under the E1-Centro wave; while the maximum displacement response of the structure under the TOM wave is 4.4 times that under the E1-Centro wave. Long-period ground motions show greater influences on displacement responses than acceleration responses for super high-rise building structures. 3) Most inelastic damage occurs at the upper 1/3 part of the super high-rise building when subjected to long-period ground motions.
基金Projects(51278367,50878159)supported by the National Natural Science Foundation of ChinaProject(90715040)supported by the Major Research Program of National Natural Science Foundation of China
文摘Analyses of the effects of some parameters were performed to determine the admittance functions in a common two-compartment building with background porosity by the imposed excitation method.Variations of the magnification factors of fluctuating internal pressures were analyzed using 96 model cases under random fluctuating external pressure,and then corresponding design equations were fitted.The results show that the Helmholtz resonance peaks of the admittance functions in both compartments increase with increasing the area of windward or partition wall opening.With increasing the volume of the compartment with an external opening,the resonance peak in this compartment at the higher Helmholtz frequency significantly decreases,at the same time,the resonance peak in the other compartment at the lower Helmholtz frequency also decreases.With increasing the volume of the compartment with background porosity,both resonance peaks in this compartment at the lower and higher Helmholtz frequencies decrease,meanwhile,the resonance peak at the lower Helmholtz frequency for the other compartment also decreases,whereas the resonance peak at the higher Helmholtz frequency increases.Both resonance peaks of the admittance functions in the two compartments decrease with increasing the amplitude of fluctuating external pressure coefficients or reference wind speed.
基金Supports from the National Natural Science Foundation of China(11672130,51508567,51478465,and 51308544)the State Key Laboratory of Mechanics and Control of Mechanical Structures(MCMS-0217G03)the State Key Laboratory for Disaster Reduction in Civil Engineering(SLDRCE16-01)。
文摘Autoclaved aerated concrete(AAC) panels have ultra-light weight,excellent thermal insulation and energy absorption,so it is an ideal building material for protective structures.To improve the blast resistance of the AAC panels,three schemes are applied to strengthen the AAC panels through spraying 4 mm thick polyurea coating from top,bottom and double-sides.In three-point bending tests,the polyurea-coated AAC panels have much higher ultimate loads than the un-coated panels,but slightly lower than those strengthened by the carbon fiber reinforced plastics(CEFRPs).Close-in explosion experiments reveal the dynamic strengthening effect of the polyurea coating.Critical scaled distances of the strengthened AAC panels are acquired,which are valuable for the engineering application of the AAC panels in the extreme loading conditions.Polyurea coatings efficiently enhance the blast resistance of the bottom and double-sided polyurea-coated AAC panels.It is interesting that the polyurea-coated AAC panels have much more excellent blast resistance than the CFRP reinforced AAC panels,although the latter have better static mechanical properties.
基金Projects(51178182,90915002)supported by the National Natural Science Foundation of ChinaProject(SLDRCE10-MB-03)supported by the Open Project of the State Key Laboratory of Disaster Reduction in Civil Engineering,China
文摘The 2-dimensional unsteady aerodynamic forces,in the context of both a thin airfoil where theory of potential flow is always applicable and a bluff bridge-deck section where separated flow is typically induced,are investigated from a point of view of whether or not they conform to the principle of linear superposition in situations of various structural motions and wind gusts.It is shown that some basic preconditions that lead to the linear superposability of the unsteady aerodynamic forces in cases of thin airfoil sections are no longer valid for a bluff section.Theoretical models of bridge aerodynamics such as the one related to flutter-buffeting analysis and those concerning aerodynamic admittance(AA)functions,however,necessitate implicitly this superposability.The contradiction revealed in this work may throw light on the perplexing problem of AA functions pertaining to the description of buffeting loads of bridge decks.Some existing theoretical AA models derived from flutter derivatives according to interrelations valid only for thin airfoil theories,which have been employed rather extensively in bridge aerodynamics,are demonstrated to be illogical.Finally,with full understanding of the preconditions of the applicability of linear superposability of the unsteady aerodynamic forces,suggestions in regard to experiment-based AA functions are presented.
基金Projects(51378396,51678452,51708074,2014M560706)supported by General Program of National Natural Science Foundation of ChinaProject(2014M560706)supported by the China Postdoctoral Science Foundation
文摘Wind data were collected during the 2011 typhoon Meari at heights of 10, 20, 30, and 40 m above the ground using a 40 m high anemometer tower in the coastal area near Shanghai Pudong International Airport. Wind speeds and directions, turbulence intensities, gust factors, and peaks were analyzed using the time records of wind speed. The results show that turbulence intensity components in longitudinal, lateral, and vertical directions decrease with mean wind speed, regardless of elevations, and the turbulence intensities are in a linear relationship with mean wind speeds. The ratios of three turbulence intensity components(i.e. Iu, Iv, Iw) at heights of 10, 20 and 40 m were calculated and equal to be 1:0.88:0.50, 1:0.84:0.57, and 1:0.9:0.49, respectively. In addition, the gust factors in three directions exhibit a reduction with increasing mean wind speed. The peak factors at different heights show a similar trend and slightly decrease with mean wind speed; average peak factors for all 10-min data from Typhoon Meari are 2.43, 2.48, and 2.47, respectively.