This study systematically investigated the influence of deposition rate on the structure,broadband opti⁃cal properties(1.0-13.0μm),and stress characteristics of Germanium(Ge)films.Additionally,a method for enhancing ...This study systematically investigated the influence of deposition rate on the structure,broadband opti⁃cal properties(1.0-13.0μm),and stress characteristics of Germanium(Ge)films.Additionally,a method for enhancing the performance of infrared filters based on rate-modulated deposition of Ge films was proposed.The optical absorption of Ge films in the short-wave infrared(SWIR)and long-wave infrared(LWIR)bands can be effectively reduced by modulating the deposition rate.As the deposition rate increases,the Ge films maintain an amorphous structure.The optical constants of the films in the 1.0-2.5μm and 2.5-13.0μm bands were precisely determined using the Cody-Lorentz model and the classical Lorentz oscillator model,respectively.Notably,high⁃er deposition rates result in a gradual increase in the refractive index.The extinction coefficient increases with the deposition rate in the SWIR region,attributed to the widening of the Urbach tail,while it decreases in the LWIR region due to the reduced absorption caused by the Ge-O stretching mode.Additionally,the films exhibit a tensile stress that decreases with increasing deposition rate.Finally,the effectiveness of the proposed fabrication method for an infrared filter with Ge films deposited at an optimized rate was demonstrated through practical examples.This work provides theoretical and technical support for the application of Ge films in high-performance infrared filters.展开更多
Near-infrared image sensors are widely used in fields such as material identification,machine vision,and autonomous driving.Lead sulfide colloidal quantum dot-based infrared photodiodes can be integrated with sil⁃icon...Near-infrared image sensors are widely used in fields such as material identification,machine vision,and autonomous driving.Lead sulfide colloidal quantum dot-based infrared photodiodes can be integrated with sil⁃icon-based readout circuits in a single step.Based on this,we propose a photodiode based on an n-i-p structure,which removes the buffer layer and further simplifies the manufacturing process of quantum dot image sensors,thus reducing manufacturing costs.Additionally,for the noise complexity in quantum dot image sensors when capturing images,traditional denoising and non-uniformity methods often do not achieve optimal denoising re⁃sults.For the noise and stripe-type non-uniformity commonly encountered in infrared quantum dot detector imag⁃es,a network architecture has been developed that incorporates multiple key modules.This network combines channel attention and spatial attention mechanisms,dynamically adjusting the importance of feature maps to en⁃hance the ability to distinguish between noise and details.Meanwhile,the residual dense feature fusion module further improves the network's ability to process complex image structures through hierarchical feature extraction and fusion.Furthermore,the pyramid pooling module effectively captures information at different scales,improv⁃ing the network's multi-scale feature representation ability.Through the collaborative effect of these modules,the network can better handle various mixed noise and image non-uniformity issues.Experimental results show that it outperforms the traditional U-Net network in denoising and image correction tasks.展开更多
The accuracy of spot centroid positioning has a significant impact on the tracking accuracy of the system and the stability of the laser link construction.In satellite laser communication systems,the use of short-wave...The accuracy of spot centroid positioning has a significant impact on the tracking accuracy of the system and the stability of the laser link construction.In satellite laser communication systems,the use of short-wave infrared wavelengths as beacon light can reduce atmospheric absorption and signal attenuation.However,there are strong non-uniformity and blind pixels in the short-wave infrared image,which makes the image distorted and leads to the decrease of spot centroid positioning accuracy.Therefore,the high-precision localization of the spot centroid of the short-wave infrared images is of great research significance.A high-precision spot centroid positioning model for short-wave infrared is proposed to correct for non-uniformity and blind pixels in short-wave infrared images and quantify the localization errors caused by the two,further model-based localization error simulations are performed,and a novel spot centroid positioning payload for satellite laser communications has been designed using the latest 640×512 planar array InGaAs shortwave infrared detector.The experimental results show that the non-uniformity of the corrected image is reduced from 7%to 0.6%,the blind pixels rejection rate reaches 100%,the frame rate can be up to 2000 Hz,and the spot centroid localization accuracy is as high as 0.1 pixel point,which realizes high-precision spot centroid localization of high-frame-frequency short-wave infrared images.展开更多
The Infrared Hyperspectral Atmospheric SounderⅡ(HIRAS-Ⅱ)is the key equipment on FengYun-3E(FY-3E)satellite,which can realize vertical atmospheric detection,featuring hyper spectral,high sensitivity and high precisio...The Infrared Hyperspectral Atmospheric SounderⅡ(HIRAS-Ⅱ)is the key equipment on FengYun-3E(FY-3E)satellite,which can realize vertical atmospheric detection,featuring hyper spectral,high sensitivity and high precision.To ensure its accuracy of detection,it is necessary to correlate their thermal models to in-orbit da⁃ta.In this work,an investigation of intelligent correlation method named Intelligent Correlation Platform for Ther⁃mal Model(ICP-TM)was established,the advanced Kriging surrogate model and efficient adaptive region opti⁃mization algorithm were introduced.After the correlation with this method for FY-3E/HIRAS-Ⅱ,the results indi⁃cate that compared with the data in orbit,the error of the thermal model has decreased from 5 K to within±1 K in cold case(10℃).Then,the correlated model is validated in hot case(20℃),and the correlated model exhibits good universality.This correlation precision is also much superiors to the general ones like 3 K in other similar lit⁃erature.Furthermore,the process is finished in 8 days using ICP-TM,the efficiency is much better than 3 months based on manual.The results show that the proposed approach significantly enhances the accuracy and efficiency of thermal model,this contributes to the precise thermal control of subsequent infrared optical payloads.展开更多
The effect of external vibration on the velocity uniformity of the moving mechanism of the angular mir⁃ror translational Fourier transform interferometer(hereinafter referred to as interferometer)can be quantitatively...The effect of external vibration on the velocity uniformity of the moving mechanism of the angular mir⁃ror translational Fourier transform interferometer(hereinafter referred to as interferometer)can be quantitatively analysed by the interferometer optical range difference velocity stability.The article proposes a more comprehen⁃sive method of analysing the optical range difference velocity uniformity for the reliability of the interferometer ki⁃nematic mechanism under the influence of on-orbit microvibration in the process of space spectroscopy detection.The method incorporates the structural response of the interferometer caused by external excitation into the stabili⁃ty analysis as one of the influencing factors,so as to reflect the reliability of the interferometer in orbit more realis⁃tically,and judge the microvibration criticality that the interferometer can withstand more accurately.At the same time,an optical surface model of the interferometer is established to further theoretically characterise the effect of microvibration on the homogeneity of the interferometric mechanism.The method discussed in the article pro⁃vides a way of thinking for the judgement of the reliability of the mechanism movement under the external excita⁃tion perturbation as well as the research on the optimisation of the mechanism control.展开更多
In this paper,we propose an RLC equivalent circuit model theory which can accurately predict the spectral response and resonance characteristics of metamaterial absorption structures,extend its design,and characterize...In this paper,we propose an RLC equivalent circuit model theory which can accurately predict the spectral response and resonance characteristics of metamaterial absorption structures,extend its design,and characterize the parameters of the model in detail.By employing this model,we conducted computations to characterize the response wavelength and bandwidth of variously sized metamaterial absorbers.A comparative analysis with Finite Difference Time Domain(FDTD)simulations demonstrated a remarkable level of consistency in the results.The designed absorbers were fabricated using micro-nano fabrication processes,and were experimentally tested to demonstrate absorption rates exceeding 90%at a wavelength of 9.28μm.The predicted results are then compared with test results.The comparison reveals good consistency in two aspects of the resonance responses,thereby confirming the rationality and accuracy of this model.展开更多
In order to meet the urgent need of infrared search and track applications for accurate identification and positioning of infrared guidance aircraft,an active-detection mid-wave infrared search and track system(ADMWIR...In order to meet the urgent need of infrared search and track applications for accurate identification and positioning of infrared guidance aircraft,an active-detection mid-wave infrared search and track system(ADMWIRSTS)based on"cat-eye effect"was developed.The ADMWIRSTS mainly consists of both a light beam control subsystem and an infrared search and track subsystem.The light beam control subsystem uses an integrated opto-mechanical two-dimensional pointing mirror to realize the control function of the azimuth and pitch directions of the system,which can cover the whole airspace range of 360°×90°.The infrared search and track subsystem uses two mid-wave infrared cooled 640×512 focal plane detectors for co-aperture beam expanding,infrared and illumination laser beam combining,infrared search,and two-stage track opto-mechanical design.In this work,the system integration design and structural finite-element analysis were conducted,the search imaging and two-stage track imaging for external scenes were performed,and the active-detection technologies were experimentally verified in the laboratory.The experimental investigation results show that the system can realize the infrared search and track imaging,and the accurate identification and positioning of the mid-wave infrared guidance,or infrared detection system through the echo of the illumination laser.The aforementioned work has important technical significance and practical application value for the development of compactly-integrated high-precision infrared search and track,and laser suppression system,and has broad application prospects in the protection of equipment,assets and infrastructures.展开更多
Chang'E-1,the orbiter circling the moon 200km above the moon surface,is the first Chinese Lunar exploration satellite.The satellite was successfully launched on 24th October 2007.There are 8 kinds of scientific pa...Chang'E-1,the orbiter circling the moon 200km above the moon surface,is the first Chinese Lunar exploration satellite.The satellite was successfully launched on 24th October 2007.There are 8 kinds of scientific payloads onboard,including the stereo camera,the laser altimeter,the Sagnac-based interferometer image spectrometer,the Gamma ray spectrometer,the X-ray spectrom-eter,the microwave radiometer,the high energy particle detector,the solar wind plasma detector and a supporting payload data management system.Chang'E-1 opened her eyes to look at the moon and took the first batch of lunar pictures after her stereo camera was switched on in 20th November 2007.Henceforth all the instruments are successfully switched on one by one.After a period of parameter adjustment and initial check out,all scientific instruments are now in their normal operating phase.In this paper,the payloads and the initial observation results are introduced.展开更多
Infrared small target detection is a common task in infrared image processing.Under limited computa⁃tional resources.Traditional methods for infrared small target detection face a trade-off between the detection rate ...Infrared small target detection is a common task in infrared image processing.Under limited computa⁃tional resources.Traditional methods for infrared small target detection face a trade-off between the detection rate and the accuracy.A fast infrared small target detection method tailored for resource-constrained conditions is pro⁃posed for the YOLOv5s model.This method introduces an additional small target detection head and replaces the original Intersection over Union(IoU)metric with Normalized Wasserstein Distance(NWD),while considering both the detection accuracy and the detection speed of infrared small targets.Experimental results demonstrate that the proposed algorithm achieves a maximum effective detection speed of 95 FPS on a 15 W TPU,while reach⁃ing a maximum effective detection accuracy of 91.9 AP@0.5,effectively improving the efficiency of infrared small target detection under resource-constrained conditions.展开更多
A novel ultra-low-power readout integrated circuit(ROIC) for 1 024×1 024 ultraviolet(UV) AlGaN focal plane arrays(FPA) with 18 μm-pitch was presented. In order to optimize power consumption for UVFPA readout cir...A novel ultra-low-power readout integrated circuit(ROIC) for 1 024×1 024 ultraviolet(UV) AlGaN focal plane arrays(FPA) with 18 μm-pitch was presented. In order to optimize power consumption for UVFPA readout circuit these methods were adopted, which including single-terminal amplifier under subthreshold region as CTIA amplifier, common current source load for source follow(SF) buffer in column pixels and level shift circuits, and time-sharing tail current source for column buffer. The smallest operational current of CTIA in pixel unit is only 8.5 nA with 3.3 V power supply by using single-terminal amplifier. The ROIC has been fabricated in SMIC 0.18 μm 1P6M mixed signal process and also achieved better performances with the novel design of bias current adjustable. Furthermore, the overall power consumption of the chip is 67.3 mW at 2 MHz in 8-outputs mode by the above methods according to the experimental results.展开更多
Taiji-2 project is the second step of Taiji program,which is to verify the required technology for Taiji-3 mission.The feasibility study of Taiji-2 is successfully finished,and some of the main progress is introduced ...Taiji-2 project is the second step of Taiji program,which is to verify the required technology for Taiji-3 mission.The feasibility study of Taiji-2 is successfully finished,and some of the main progress is introduced here.展开更多
Microgravity science is an important branch of space science.Its major objective is to study the laws of materials movement in microgravity,as well as to reveal the influence of gravity on the movement of materials in...Microgravity science is an important branch of space science.Its major objective is to study the laws of materials movement in microgravity,as well as to reveal the influence of gravity on the movement of materials in different gravity environments.Application researches relevant to these basic studies are also important contents of microgravity science.The advanced subjects,to some extent,reflect the ability of human beings to understand nature and the R&D level in this field in various countries.In this paper,the recent progress and the latest achievements of microgravity science and application researches in China aboard space platforms such as the Core Capsule Tianhe of the China Space Station(CSS)and satellites,as well as utilizing ground-based short-term microgravity facilities such as the Drop Tower Beijing and TUFF,are summarized,which cover the following sub-disciplines:microgravity fluid physics,microgravity combustion science,space materials science,space fundamental physics,space bio-technology,and relevant space technology applications.展开更多
China has great progress in the technology and application of ocean color remote sensing during 2004-2006. In this report, firstly, four major technical advances are displaying, including (1) the vector radiative tran...China has great progress in the technology and application of ocean color remote sensing during 2004-2006. In this report, firstly, four major technical advances are displaying, including (1) the vector radiative transfer numerical model of coupled ocean-atmosphere system; (2) the atmospheric correction algorithm specialized on Chinese high turbid water; (3) systematical research of hyper-spectrum ocean color remote sensing; (4) local algorithms of oceanic parameters, like ocean color components, ocean primary productivity, water transparency, water quality parameters, etc. On the foundation of technical advances, ocean color remote sensing takes effect on ocean environment monitoring, with four major kinds of application systems, namely, (1) the automatic multi-satellites data receiving, processing and application system; (2) the shipboard satellite data receiving and processing system for fishery ground information; (3) Coastal water quality monitoring system, integrating satellite and airborne remote sensing technology and ship measurement; (4) the preliminary system of airborne ocean color remote sensing application system. Finally, the prospective development of Chinese ocean color remote sensing is brought forward. With Chinese second ocean color satellite (HY-1B) orbiting, great strides will take place in Chinese ocean color information accumulation and application.展开更多
Environment and disaster monitoring and forecasting small satellite constellation A and B satellites(HJ-1-A,B) are called "environment and disaster reduction satellites A and B" for short.The constellation a...Environment and disaster monitoring and forecasting small satellite constellation A and B satellites(HJ-1-A,B) are called "environment and disaster reduction satellites A and B" for short.The constellation adopts a 10:30LT sun-synchronous circular orbit,with orbit altitude of 649km.HJ1-A and HJ-1-B are distributed with a phase difference of 180° in the same orbital plane,so as to enhance the time resolution of earth observation.The satellites have orbit maintenance capability,the lifetime is 3 years.Both satellites adopt CAST968 platforms.Two wide-coverage multispectral CCD cameras with resolution 30m and width 700km,a super-spectral imager with resolution 100m and width 50km as well as a data transmission subsystem of 120Mbit/s are deployed on HJ-1-A,which also carries Ka communication testing equipment of Thailand.HJ-1-B has two wide-coverage multispectral CCD cameras(the same as satellite A),one infrared camera with resolution 150m and width 720km and a data transmission subsystem of 60Mbit/s.The coverage period of the wide-coverage multispectral CCD camera is 48 hours.The revisit period of super-spectral imager is 96 hours and the coverage period ofinfrared camera is 96 hours.展开更多
With the human space exploration activities, space life science is an emerging interdiscipline,which covers a wide range of researches. Based on our country's manned space station and recoverable satellite science...With the human space exploration activities, space life science is an emerging interdiscipline,which covers a wide range of researches. Based on our country's manned space station and recoverable satellite science experimental platform, the development of space life science research is very important to acquire new knowledge or new technological innovation, to give further services to the human space exploration activities,to improve the national economic and social development. Both ground-based and flight applied studies were continuously performed in the previous 2 years. Here, we review and summarize the researches on space life sciences contributed by Chinese scientists.展开更多
In the realm of near-infrared spectroscopy,the detection of molecules has been achieved using on-chip waveguides and resonators.In the mid-infrared band,the integration and sensitivity of chemical sensing chips are of...In the realm of near-infrared spectroscopy,the detection of molecules has been achieved using on-chip waveguides and resonators.In the mid-infrared band,the integration and sensitivity of chemical sensing chips are often constrained by the reliance on off-chip light sources and detectors.In this study,we demonstrate an InAs/GaAsSb superlattice mid-infrared waveguide integrated detector.The GaAsSb waveguide layer and the InAs/GaAsSb superlattice absorbing layer are connected through evanescent coupling,facilitating efficient and highquality detection of mid-infrared light with minimal loss.We conducted a simulation to analyze the photoelectric characteristics of the device.Additionally,we investigated the factors that affect the integration of the InAs/GaAs⁃Sb superlattice photodetector and the GaAsSb waveguide.Optimal thicknesses and lengths for the absorption lay⁃er are determined.When the absorption layer has a thickness of 0.3μm and a length of 50μm,the noise equiva⁃lent power reaches its minimum value,and the quantum efficiency can achieve a value of 68.9%.The utilization of waveguide detectors constructed with Ⅲ-Ⅴ materials offers a more convenient means of integrating mid-infra⁃red light sources and achieving photoelectric detection chips.展开更多
The development of InGaAs/InP single-photon avalanche photodiodes(SPADs)necessitates the utiliza-tion of a two-element diffusion technique to achieve accurate manipulation of the multiplication width and the dis-tribu...The development of InGaAs/InP single-photon avalanche photodiodes(SPADs)necessitates the utiliza-tion of a two-element diffusion technique to achieve accurate manipulation of the multiplication width and the dis-tribution of its electric field.Regarding the issue of accurately predicting the depth of diffusion in InGaAs/InP SPAD,simulation analysis and device development were carried out,focusing on the dual diffusion behavior of zinc atoms.A formula of X_(j)=k√t-t_(0)+c to quantitatively predict the diffusion depth is obtained by fitting the simulated twice-diffusion depths based on a two-dimensional(2D)model.The 2D impurity morphologies and the one-dimensional impurity profiles for the dual-diffused region are characterized by using scanning electron micros-copy and secondary ion mass spectrometry as a function of the diffusion depth,respectively.InGaAs/InP SPAD devices with different dual-diffusion conditions are also fabricated,which show breakdown behaviors well consis-tent with the simulated results under the same junction geometries.The dark count rate(DCR)of the device de-creased as the multiplication width increased,as indicated by the results.DCRs of 2×10^(6),1×10^(5),4×10^(4),and 2×10^(4) were achieved at temperatures of 300 K,273 K,263 K,and 253 K,respectively,with a bias voltage of 3 V,when the multiplication width was 1.5µm.These results demonstrate an effective prediction route for accu-rately controlling the dual-diffused zinc junction geometry in InP-based planar device processing.展开更多
Hexagonal boron nitride(h-BN)is found to have widespread application,owing to its outstanding properties,including gate dielectrics,passivation layers,and tunneling layers.The current studies on the funda⁃mental physi...Hexagonal boron nitride(h-BN)is found to have widespread application,owing to its outstanding properties,including gate dielectrics,passivation layers,and tunneling layers.The current studies on the funda⁃mental physical properties of these ultrathin h-BN films and the electron tunneling effect among them are inade⁃quate.In this work,the effective mass in h-BN was successfully determined through a combined approach of ex⁃perimental and theoretical research methods by fitting the current-voltage curves of metal/insulator/metal struc⁃tures.It was observed that within a range of 4-22 layers,the effective mass of h-BN exhibits a monotonic de⁃crease with an increase in the number of layers.The physical parameters of the Fowler-Nordheim tunneling model in the context of electron tunneling in h-BN are precisely ascertained by utilizing the extracted effective mass.Ad⁃ditionally,the impact of fixed charges at the metal/h-BN interface and various metal electrode types on FowlerNordheim tunneling within this structure is investigated utilizing this physical parameter in Sentaurus TCAD soft⁃ware.This work is informative and instructive in promoting applications in the fields of h-BN related infrared physics and technology.展开更多
The response wavelength of the blocked-impurity-band(BIB)structured infrared detector can reach 200µm,which is the most important very long wavelength infrared astronomical detector.The ion implantation method gr...The response wavelength of the blocked-impurity-band(BIB)structured infrared detector can reach 200µm,which is the most important very long wavelength infrared astronomical detector.The ion implantation method greatly simplifies the fabrication process of the device,but it is easy to cause lattice damage,introduce crystalline defects,and lead to the increase of the dark current of detectors.Herein,the boron-doped germanium ion implantation process was studied,and the involved lattice damage mechanism was discussed.Experimental conditions involved using 80 keV energy for boron ion implantation,with doses ranging from 1×10^(13)cm^(-2)to 3×10^(15)cm^(-2).After implantation,thermal annealing at 450℃was implemented to optimize dopant activation and mitigate the effects of ion implantation.Various sophisticated characterization techniques,including X-ray dif⁃fraction(XRD),Raman spectroscopy,X-ray photoelectron spectroscopy(XPS),and secondary ion mass spec⁃trometry(SIMS)were used to clarify lattice damage.At lower doses,no notable structural alterations were ob⁃served.However,as the dosage increased,specific micro distortions became apparent,which could be attributed to point defects and residual strain.The created lattice damage was recovered by thermal treatment,however,an irreversible strain induced by implantation still existed at heavily dosed samples.展开更多
基金Supported by the National Natural Science Foundation of China(62275053,62275256)the National key Research and Development Program of China(2021YFB3701500)+1 种基金the Youth Innovation Promotion Association of the Chinese Academy of Sciences(2023248)the Eastern Talent Plan Youth Project 2022,the Shanghai Key Laboratory of Optical Coatings and Spectral Modulation(23dz2260500).
文摘This study systematically investigated the influence of deposition rate on the structure,broadband opti⁃cal properties(1.0-13.0μm),and stress characteristics of Germanium(Ge)films.Additionally,a method for enhancing the performance of infrared filters based on rate-modulated deposition of Ge films was proposed.The optical absorption of Ge films in the short-wave infrared(SWIR)and long-wave infrared(LWIR)bands can be effectively reduced by modulating the deposition rate.As the deposition rate increases,the Ge films maintain an amorphous structure.The optical constants of the films in the 1.0-2.5μm and 2.5-13.0μm bands were precisely determined using the Cody-Lorentz model and the classical Lorentz oscillator model,respectively.Notably,high⁃er deposition rates result in a gradual increase in the refractive index.The extinction coefficient increases with the deposition rate in the SWIR region,attributed to the widening of the Urbach tail,while it decreases in the LWIR region due to the reduced absorption caused by the Ge-O stretching mode.Additionally,the films exhibit a tensile stress that decreases with increasing deposition rate.Finally,the effectiveness of the proposed fabrication method for an infrared filter with Ge films deposited at an optimized rate was demonstrated through practical examples.This work provides theoretical and technical support for the application of Ge films in high-performance infrared filters.
基金Supported by the National key research and development program in the 14th five year plan 2021YFA1200700)the National Natural Science Foundation of China(62535018,62431025,62561160113)the Natural Science Foundation of Shanghai(23ZR1473400).
文摘Near-infrared image sensors are widely used in fields such as material identification,machine vision,and autonomous driving.Lead sulfide colloidal quantum dot-based infrared photodiodes can be integrated with sil⁃icon-based readout circuits in a single step.Based on this,we propose a photodiode based on an n-i-p structure,which removes the buffer layer and further simplifies the manufacturing process of quantum dot image sensors,thus reducing manufacturing costs.Additionally,for the noise complexity in quantum dot image sensors when capturing images,traditional denoising and non-uniformity methods often do not achieve optimal denoising re⁃sults.For the noise and stripe-type non-uniformity commonly encountered in infrared quantum dot detector imag⁃es,a network architecture has been developed that incorporates multiple key modules.This network combines channel attention and spatial attention mechanisms,dynamically adjusting the importance of feature maps to en⁃hance the ability to distinguish between noise and details.Meanwhile,the residual dense feature fusion module further improves the network's ability to process complex image structures through hierarchical feature extraction and fusion.Furthermore,the pyramid pooling module effectively captures information at different scales,improv⁃ing the network's multi-scale feature representation ability.Through the collaborative effect of these modules,the network can better handle various mixed noise and image non-uniformity issues.Experimental results show that it outperforms the traditional U-Net network in denoising and image correction tasks.
基金Supported by the Short-wave Infrared Camera Systems(B025F40622024)。
文摘The accuracy of spot centroid positioning has a significant impact on the tracking accuracy of the system and the stability of the laser link construction.In satellite laser communication systems,the use of short-wave infrared wavelengths as beacon light can reduce atmospheric absorption and signal attenuation.However,there are strong non-uniformity and blind pixels in the short-wave infrared image,which makes the image distorted and leads to the decrease of spot centroid positioning accuracy.Therefore,the high-precision localization of the spot centroid of the short-wave infrared images is of great research significance.A high-precision spot centroid positioning model for short-wave infrared is proposed to correct for non-uniformity and blind pixels in short-wave infrared images and quantify the localization errors caused by the two,further model-based localization error simulations are performed,and a novel spot centroid positioning payload for satellite laser communications has been designed using the latest 640×512 planar array InGaAs shortwave infrared detector.The experimental results show that the non-uniformity of the corrected image is reduced from 7%to 0.6%,the blind pixels rejection rate reaches 100%,the frame rate can be up to 2000 Hz,and the spot centroid localization accuracy is as high as 0.1 pixel point,which realizes high-precision spot centroid localization of high-frame-frequency short-wave infrared images.
基金Supported by the National Key Research and Development Program of China(2022YFB3904803)。
文摘The Infrared Hyperspectral Atmospheric SounderⅡ(HIRAS-Ⅱ)is the key equipment on FengYun-3E(FY-3E)satellite,which can realize vertical atmospheric detection,featuring hyper spectral,high sensitivity and high precision.To ensure its accuracy of detection,it is necessary to correlate their thermal models to in-orbit da⁃ta.In this work,an investigation of intelligent correlation method named Intelligent Correlation Platform for Ther⁃mal Model(ICP-TM)was established,the advanced Kriging surrogate model and efficient adaptive region opti⁃mization algorithm were introduced.After the correlation with this method for FY-3E/HIRAS-Ⅱ,the results indi⁃cate that compared with the data in orbit,the error of the thermal model has decreased from 5 K to within±1 K in cold case(10℃).Then,the correlated model is validated in hot case(20℃),and the correlated model exhibits good universality.This correlation precision is also much superiors to the general ones like 3 K in other similar lit⁃erature.Furthermore,the process is finished in 8 days using ICP-TM,the efficiency is much better than 3 months based on manual.The results show that the proposed approach significantly enhances the accuracy and efficiency of thermal model,this contributes to the precise thermal control of subsequent infrared optical payloads.
文摘The effect of external vibration on the velocity uniformity of the moving mechanism of the angular mir⁃ror translational Fourier transform interferometer(hereinafter referred to as interferometer)can be quantitatively analysed by the interferometer optical range difference velocity stability.The article proposes a more comprehen⁃sive method of analysing the optical range difference velocity uniformity for the reliability of the interferometer ki⁃nematic mechanism under the influence of on-orbit microvibration in the process of space spectroscopy detection.The method incorporates the structural response of the interferometer caused by external excitation into the stabili⁃ty analysis as one of the influencing factors,so as to reflect the reliability of the interferometer in orbit more realis⁃tically,and judge the microvibration criticality that the interferometer can withstand more accurately.At the same time,an optical surface model of the interferometer is established to further theoretically characterise the effect of microvibration on the homogeneity of the interferometric mechanism.The method discussed in the article pro⁃vides a way of thinking for the judgement of the reliability of the mechanism movement under the external excita⁃tion perturbation as well as the research on the optimisation of the mechanism control.
基金Supported by the National Natural Science Foundation of China(62174092)the Open Fund of State Key Laboratory of Infrared Physics(SITP-NLIST-ZD-2023-04)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDB0580000)。
文摘In this paper,we propose an RLC equivalent circuit model theory which can accurately predict the spectral response and resonance characteristics of metamaterial absorption structures,extend its design,and characterize the parameters of the model in detail.By employing this model,we conducted computations to characterize the response wavelength and bandwidth of variously sized metamaterial absorbers.A comparative analysis with Finite Difference Time Domain(FDTD)simulations demonstrated a remarkable level of consistency in the results.The designed absorbers were fabricated using micro-nano fabrication processes,and were experimentally tested to demonstrate absorption rates exceeding 90%at a wavelength of 9.28μm.The predicted results are then compared with test results.The comparison reveals good consistency in two aspects of the resonance responses,thereby confirming the rationality and accuracy of this model.
基金Supported by the Fundamental Scientific Research Plan of China(JCKY2021130B033)。
文摘In order to meet the urgent need of infrared search and track applications for accurate identification and positioning of infrared guidance aircraft,an active-detection mid-wave infrared search and track system(ADMWIRSTS)based on"cat-eye effect"was developed.The ADMWIRSTS mainly consists of both a light beam control subsystem and an infrared search and track subsystem.The light beam control subsystem uses an integrated opto-mechanical two-dimensional pointing mirror to realize the control function of the azimuth and pitch directions of the system,which can cover the whole airspace range of 360°×90°.The infrared search and track subsystem uses two mid-wave infrared cooled 640×512 focal plane detectors for co-aperture beam expanding,infrared and illumination laser beam combining,infrared search,and two-stage track opto-mechanical design.In this work,the system integration design and structural finite-element analysis were conducted,the search imaging and two-stage track imaging for external scenes were performed,and the active-detection technologies were experimentally verified in the laboratory.The experimental investigation results show that the system can realize the infrared search and track imaging,and the accurate identification and positioning of the mid-wave infrared guidance,or infrared detection system through the echo of the illumination laser.The aforementioned work has important technical significance and practical application value for the development of compactly-integrated high-precision infrared search and track,and laser suppression system,and has broad application prospects in the protection of equipment,assets and infrastructures.
文摘Chang'E-1,the orbiter circling the moon 200km above the moon surface,is the first Chinese Lunar exploration satellite.The satellite was successfully launched on 24th October 2007.There are 8 kinds of scientific payloads onboard,including the stereo camera,the laser altimeter,the Sagnac-based interferometer image spectrometer,the Gamma ray spectrometer,the X-ray spectrom-eter,the microwave radiometer,the high energy particle detector,the solar wind plasma detector and a supporting payload data management system.Chang'E-1 opened her eyes to look at the moon and took the first batch of lunar pictures after her stereo camera was switched on in 20th November 2007.Henceforth all the instruments are successfully switched on one by one.After a period of parameter adjustment and initial check out,all scientific instruments are now in their normal operating phase.In this paper,the payloads and the initial observation results are introduced.
文摘Infrared small target detection is a common task in infrared image processing.Under limited computa⁃tional resources.Traditional methods for infrared small target detection face a trade-off between the detection rate and the accuracy.A fast infrared small target detection method tailored for resource-constrained conditions is pro⁃posed for the YOLOv5s model.This method introduces an additional small target detection head and replaces the original Intersection over Union(IoU)metric with Normalized Wasserstein Distance(NWD),while considering both the detection accuracy and the detection speed of infrared small targets.Experimental results demonstrate that the proposed algorithm achieves a maximum effective detection speed of 95 FPS on a 15 W TPU,while reach⁃ing a maximum effective detection accuracy of 91.9 AP@0.5,effectively improving the efficiency of infrared small target detection under resource-constrained conditions.
文摘A novel ultra-low-power readout integrated circuit(ROIC) for 1 024×1 024 ultraviolet(UV) AlGaN focal plane arrays(FPA) with 18 μm-pitch was presented. In order to optimize power consumption for UVFPA readout circuit these methods were adopted, which including single-terminal amplifier under subthreshold region as CTIA amplifier, common current source load for source follow(SF) buffer in column pixels and level shift circuits, and time-sharing tail current source for column buffer. The smallest operational current of CTIA in pixel unit is only 8.5 nA with 3.3 V power supply by using single-terminal amplifier. The ROIC has been fabricated in SMIC 0.18 μm 1P6M mixed signal process and also achieved better performances with the novel design of bias current adjustable. Furthermore, the overall power consumption of the chip is 67.3 mW at 2 MHz in 8-outputs mode by the above methods according to the experimental results.
基金Supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(XDA15021100)the National Natural Science Foundation of China(12147103)the Fundamental Research Funds for the Central Universities。
文摘Taiji-2 project is the second step of Taiji program,which is to verify the required technology for Taiji-3 mission.The feasibility study of Taiji-2 is successfully finished,and some of the main progress is introduced here.
文摘Microgravity science is an important branch of space science.Its major objective is to study the laws of materials movement in microgravity,as well as to reveal the influence of gravity on the movement of materials in different gravity environments.Application researches relevant to these basic studies are also important contents of microgravity science.The advanced subjects,to some extent,reflect the ability of human beings to understand nature and the R&D level in this field in various countries.In this paper,the recent progress and the latest achievements of microgravity science and application researches in China aboard space platforms such as the Core Capsule Tianhe of the China Space Station(CSS)and satellites,as well as utilizing ground-based short-term microgravity facilities such as the Drop Tower Beijing and TUFF,are summarized,which cover the following sub-disciplines:microgravity fluid physics,microgravity combustion science,space materials science,space fundamental physics,space bio-technology,and relevant space technology applications.
文摘China has great progress in the technology and application of ocean color remote sensing during 2004-2006. In this report, firstly, four major technical advances are displaying, including (1) the vector radiative transfer numerical model of coupled ocean-atmosphere system; (2) the atmospheric correction algorithm specialized on Chinese high turbid water; (3) systematical research of hyper-spectrum ocean color remote sensing; (4) local algorithms of oceanic parameters, like ocean color components, ocean primary productivity, water transparency, water quality parameters, etc. On the foundation of technical advances, ocean color remote sensing takes effect on ocean environment monitoring, with four major kinds of application systems, namely, (1) the automatic multi-satellites data receiving, processing and application system; (2) the shipboard satellite data receiving and processing system for fishery ground information; (3) Coastal water quality monitoring system, integrating satellite and airborne remote sensing technology and ship measurement; (4) the preliminary system of airborne ocean color remote sensing application system. Finally, the prospective development of Chinese ocean color remote sensing is brought forward. With Chinese second ocean color satellite (HY-1B) orbiting, great strides will take place in Chinese ocean color information accumulation and application.
文摘Environment and disaster monitoring and forecasting small satellite constellation A and B satellites(HJ-1-A,B) are called "environment and disaster reduction satellites A and B" for short.The constellation adopts a 10:30LT sun-synchronous circular orbit,with orbit altitude of 649km.HJ1-A and HJ-1-B are distributed with a phase difference of 180° in the same orbital plane,so as to enhance the time resolution of earth observation.The satellites have orbit maintenance capability,the lifetime is 3 years.Both satellites adopt CAST968 platforms.Two wide-coverage multispectral CCD cameras with resolution 30m and width 700km,a super-spectral imager with resolution 100m and width 50km as well as a data transmission subsystem of 120Mbit/s are deployed on HJ-1-A,which also carries Ka communication testing equipment of Thailand.HJ-1-B has two wide-coverage multispectral CCD cameras(the same as satellite A),one infrared camera with resolution 150m and width 720km and a data transmission subsystem of 60Mbit/s.The coverage period of the wide-coverage multispectral CCD camera is 48 hours.The revisit period of super-spectral imager is 96 hours and the coverage period ofinfrared camera is 96 hours.
文摘With the human space exploration activities, space life science is an emerging interdiscipline,which covers a wide range of researches. Based on our country's manned space station and recoverable satellite science experimental platform, the development of space life science research is very important to acquire new knowledge or new technological innovation, to give further services to the human space exploration activities,to improve the national economic and social development. Both ground-based and flight applied studies were continuously performed in the previous 2 years. Here, we review and summarize the researches on space life sciences contributed by Chinese scientists.
基金Supported by the National Natural Science Foundation of China(NSFC)(61904183,61974152,62104237,62004205)the Youth Innovation Promotion Association of the Chinese Academy of Sciences(Y202057)+1 种基金Shanghai Science and Technology Committee Rising-Star Program(20QA1410500)Shanghai Sail Plans(21YF1455000)。
文摘In the realm of near-infrared spectroscopy,the detection of molecules has been achieved using on-chip waveguides and resonators.In the mid-infrared band,the integration and sensitivity of chemical sensing chips are often constrained by the reliance on off-chip light sources and detectors.In this study,we demonstrate an InAs/GaAsSb superlattice mid-infrared waveguide integrated detector.The GaAsSb waveguide layer and the InAs/GaAsSb superlattice absorbing layer are connected through evanescent coupling,facilitating efficient and highquality detection of mid-infrared light with minimal loss.We conducted a simulation to analyze the photoelectric characteristics of the device.Additionally,we investigated the factors that affect the integration of the InAs/GaAs⁃Sb superlattice photodetector and the GaAsSb waveguide.Optimal thicknesses and lengths for the absorption lay⁃er are determined.When the absorption layer has a thickness of 0.3μm and a length of 50μm,the noise equiva⁃lent power reaches its minimum value,and the quantum efficiency can achieve a value of 68.9%.The utilization of waveguide detectors constructed with Ⅲ-Ⅴ materials offers a more convenient means of integrating mid-infra⁃red light sources and achieving photoelectric detection chips.
基金Supported by Shanghai Natural Science Foundation(22ZR1472600).
文摘The development of InGaAs/InP single-photon avalanche photodiodes(SPADs)necessitates the utiliza-tion of a two-element diffusion technique to achieve accurate manipulation of the multiplication width and the dis-tribution of its electric field.Regarding the issue of accurately predicting the depth of diffusion in InGaAs/InP SPAD,simulation analysis and device development were carried out,focusing on the dual diffusion behavior of zinc atoms.A formula of X_(j)=k√t-t_(0)+c to quantitatively predict the diffusion depth is obtained by fitting the simulated twice-diffusion depths based on a two-dimensional(2D)model.The 2D impurity morphologies and the one-dimensional impurity profiles for the dual-diffused region are characterized by using scanning electron micros-copy and secondary ion mass spectrometry as a function of the diffusion depth,respectively.InGaAs/InP SPAD devices with different dual-diffusion conditions are also fabricated,which show breakdown behaviors well consis-tent with the simulated results under the same junction geometries.The dark count rate(DCR)of the device de-creased as the multiplication width increased,as indicated by the results.DCRs of 2×10^(6),1×10^(5),4×10^(4),and 2×10^(4) were achieved at temperatures of 300 K,273 K,263 K,and 253 K,respectively,with a bias voltage of 3 V,when the multiplication width was 1.5µm.These results demonstrate an effective prediction route for accu-rately controlling the dual-diffused zinc junction geometry in InP-based planar device processing.
基金Supported by the National Natural Science Foundation of China(62074085,62104118)。
文摘Hexagonal boron nitride(h-BN)is found to have widespread application,owing to its outstanding properties,including gate dielectrics,passivation layers,and tunneling layers.The current studies on the funda⁃mental physical properties of these ultrathin h-BN films and the electron tunneling effect among them are inade⁃quate.In this work,the effective mass in h-BN was successfully determined through a combined approach of ex⁃perimental and theoretical research methods by fitting the current-voltage curves of metal/insulator/metal struc⁃tures.It was observed that within a range of 4-22 layers,the effective mass of h-BN exhibits a monotonic de⁃crease with an increase in the number of layers.The physical parameters of the Fowler-Nordheim tunneling model in the context of electron tunneling in h-BN are precisely ascertained by utilizing the extracted effective mass.Ad⁃ditionally,the impact of fixed charges at the metal/h-BN interface and various metal electrode types on FowlerNordheim tunneling within this structure is investigated utilizing this physical parameter in Sentaurus TCAD soft⁃ware.This work is informative and instructive in promoting applications in the fields of h-BN related infrared physics and technology.
基金Supported by National Key R&D Program of China(2023YFA1608701)National Natural Science Foundation of China(62274168,11933006,U2141240)Hangzhou Leading Innovation and Entrepreneurship Team(TD2020002)。
文摘The response wavelength of the blocked-impurity-band(BIB)structured infrared detector can reach 200µm,which is the most important very long wavelength infrared astronomical detector.The ion implantation method greatly simplifies the fabrication process of the device,but it is easy to cause lattice damage,introduce crystalline defects,and lead to the increase of the dark current of detectors.Herein,the boron-doped germanium ion implantation process was studied,and the involved lattice damage mechanism was discussed.Experimental conditions involved using 80 keV energy for boron ion implantation,with doses ranging from 1×10^(13)cm^(-2)to 3×10^(15)cm^(-2).After implantation,thermal annealing at 450℃was implemented to optimize dopant activation and mitigate the effects of ion implantation.Various sophisticated characterization techniques,including X-ray dif⁃fraction(XRD),Raman spectroscopy,X-ray photoelectron spectroscopy(XPS),and secondary ion mass spec⁃trometry(SIMS)were used to clarify lattice damage.At lower doses,no notable structural alterations were ob⁃served.However,as the dosage increased,specific micro distortions became apparent,which could be attributed to point defects and residual strain.The created lattice damage was recovered by thermal treatment,however,an irreversible strain induced by implantation still existed at heavily dosed samples.